§ 150.021 AMENDMENTS, DELETIONS AND ADDITIONS.
   (A)   In residential dwelling units the load side of the meter to the line side of the panel shall be installed in a raceway, i.e., PVC conduit.
   (B)   The minimum service for a new single-family dwelling unit shall be 200 AMPS.
   (C)   In the kitchen area there shall be a separate circuit for the refrigerator.
   (D)   Circuits for kitchen counter outlets shall be alternately spaced so that no two adjacent outlets are on the same circuit.
   (E)   Whenever any electrical wiring or any other electrical equipment shall have been inspected and approved, it shall thereafter be unlawful for any person to alter, damage or interfere with the same without the authority of the Building Official.
(Ord. 02-13, passed 1-28-13; Am. Ord. 01-16, passed 2-8-16)