§ 153.211 MINIMUM NUMBER OF LOADING SPACES REQUIRED.
   The minimum number of off-street loading spaces shall be not less than that as set forth in the following table:
   (A)   Each use of a business, institutional, personal or professional service nature including but not limited to a business office, hotel, motel, recreational or entertainment type use shall provide loading spaces based on gross floor area as follows:
 
Gross Floor Area (Sq. Ft.)
Minimum Loading Spaces Required
Under 10,000
0
10,000 to 100,000
1
100,000 to 350,000
2
350,000 or more
2 plus 1 for each additional square feet or fraction thereof exceeding 350,000 square feet
 
   (B)   Each commercial or industrial type use involving the retail or wholesale exchange, sale, storage, processing or manufacturing of merchandise or personal property of any type, which is permitted in any commercial or manufacturing district, shall provide loading spaces based on gross floor area as follows:
Gross Floor Area (Sq. Ft.)
Maximum Loading Spaces Required
Gross Floor Area (Sq. Ft.)
Maximum Loading Spaces Required
Under 5,000
0
5,000 to 10,000
1
10,000 to 30,000
2
30,000 to 90,000
3
90,000 to 150,000
4
150,000 to 250,000
5
250,000 or more
5 plus 1 for each 80,000 square feet or fraction thereof exceeding 250,000 square feet
 
('80 Code, § 1193.12) (Ord. 68-86, passed 12-8-86) Penalty, see § 153.999