§ 151.107 INDUSTRIAL DISTRICT BULK REGULATIONS.
   I-1 Limited Industrial District
 
   I-2 General Industrial District
 
District
Minimum Front Yard Setback
Minimum Side Yard Setback
Minimum Rear Yard Setback
Maximum Lot Coverage
I-1 Limited Industrial District
30 ft.1, 3
5 ft. or 10% of lot width2
30 ft.3
60%
I-2 General Industrial District
30 ft.1, 3
5 ft. or 10% of lot width2
30 ft.3
-
1   Where lots within the same block and comprising 40% of the frontage on the same street are already developed on the effective date of this chapter with front yards with an average depth of less than 30 feet, then such average depth shall be the required front yard depth for such frontage in said block.
2   Side yard does not need to exceed 20 feet.
3   Setback shall be increased to a minimum of 50 feet if adjacent to a residence district.
 
(Ord. 2015-08, § 9.03, passed 6-23-2015)