(a) In Industrial Zoning Districts, at no point on the boundary of a Residence Zoning District shall the sound pressure level of any individual operation or plant, or the combined operations of any person, exceed the decibel levels in the designated octave bands as shown below for the zoning districts indicated as measured under the test procedures established by Section 632.13.
Octave Band Maximum Sound Pressure Levels
Center (dB) Along District Boundaries
Frequency
(Hz) Residence Daytime
Center (dB) Along District Boundaries
Frequency
(Hz) Residence Daytime
31.5 77
63 76
125 70
250 62
500 56
1,000 50
2,000 44
4,000 39
8,000 37
A-scale levels (for monitoring purposes) 60 dB(A)
31.5 67
63 66
125 60
250 52
500 46
1,000 40
2,000 34
4,000 29
8,000 27
A-scale levels (for monitoring purposes) 50 dB(A)
(b) In Residence Zoning Districts, any property use shall conform to the performance standards stated above for Residence District boundaries, provided that the performance standards shall in every case be applied at the boundaries of the lot on which such use is established.