§ 152.32 SEWER SUPPLY.
   (A)   Connections. Each independent trailer space or mobile home space shall be provided with at least a three-inch sewer connection. The sewer connection shall be provided with suitable fittings as adaptors so that a water-tight connection can be made between a trailer or mobile home drain and the sewer connection. Such individual trailer or mobile home connections shall be constructed so that they can be closed when not linked to a trailer or mobile home and shall be capped so as to prevent escape odors.
(1976 Code, § 10-525)
   (B)   Sewer lines.
      (1)   Sewer lines shall be constructed in accordance with plans approved by the Health Officer and in accordance with the recommendations of such Health Officer.
      (2)   All sewer lines shall be adequately vented, and shall be laid with sufficient earth to prevent breakage from traffic.
(1976 Code, § 10-526)
   (C)   Sewage disposal. It shall be unlawful to permit any waste water from sinks, baths, showers or other plumbing fixtures in any trailer or mobile home court to be deposited upon the surface of the ground and all such fixtures, when in use, must be connected to the city sewer system.
(1976 Code, § 10-527) Penalty, see § 10.99