§ 152.30 SERVICE BUILDINGS.
   (A)   (1)   Trailer courts that accommodate dependent trailers shall provide at least the following facilities within a service building:
         (a)   For one to ten dependent trailer spaces, two flush-type toilets and lavatories and one shower or bath tub for females; one flush-type toilet, one urinal, one lavatory and one shower or bath tub for males; and one slop-water closet consisting of at least one flush-type toilet bowl receptacle for emptying containers of human excreta, with an adequate supply of hot and cold running water for cleaning such containers; this slop-water closet shall be a separate room of a service building with a single direct opening to the outside; and
         (b)   For more than ten dependent trailers, the following additional fixtures shall be provided; one lavatory and one shower or bath tub for each sex for every additional ten dependent trailers or fraction thereof; one water closet for females for every additional ten dependent trailers or fraction thereof; one water closet for males for every additional 15 dependent trailers or fraction thereof; provided that, urinals may be substituted for not more than one-third of the additional water closets required under this division (A)(1)(b).
      (2)   Dependent trailer spaces shall be not more than 200 feet from a service building.
(1976 Code, § 10-518)
   (B)   In addition to other requirements listed previously, the service building shall comply with the following specifications:
      (1)   Be located 25 feet or more from any trailer; provided, however, that, this requirement shall not apply to construction lawfully in existence at the effective date of this chapter;
      (2)   Be of permanent construction, lighted with natural lighting by windows or skylights at least 12% of the floor area and artificial lighting;
      (3)   Be of moisture-resistant material;
      (4)   Have adequate heating facilities to maintain a temperature of 70°F at a distance of three feet above floor level under ordinary minimum winter conditions and to supply adequate hot water during time of peak demands. These facilities should be maintained in safe and good working condition; and
      (5)   Have all rooms well-ventilated and all exterior openings effectively screened with no larger than 16 mesh screen.
(1976 Code, § 10-519)
   (C)   (1)   Laundry facilities shall be provided in the ratio of at least one clothes washing machine and one laundry tray to every 30 dependent trailer spaces, and shall be in a separate room of a service building or in a separate building.
      (2)   Clothes drying facilities shall be available without charge for all spaces. Facilities may be provided on individual spaces or centrally located for community use; and they may be outdoor clothes drying racks or mechanical drying facilities in a service building.
(1976 Code, § 10-520) Penalty, see § 10.99