761.06 SITE PLAN AND VICINITY MAP REQUIREMENTS.
   Each application for a permit to drill a gas/oil well shall be accomplished by all necessary information required for a State permit, but not less than the following:
   (a)   The owner's name and addresses and current lot lines of all properties within the proposed drilling unit.
   (b)   The current locations, dimensions, and use of all buildings and structures located within 200 feet of the drilling head.
   (c)   The proposed locations of the well and all associated appliances and facilities such as wellhead, piping, separators, scrubbers, tank batteries, access roads, dikes, fence and the like.
   (d)   The proposed landscaping, screening, and restoration plans.
   (e)   The proposed location of pipelines to be utilized to transmit the gas and or oil to offsite locations and facilities to be established at the receiving facility locations(s).
   (f)   For emergency purposes a schematic diagram of all flowlines, connections and gate valves outside the compound; the diagram shall be modified and resubmitted to the City at any time that a change in equipment or facilities occurs.
   (g)   Specific plans for the removal, disposal methods and disposal site of all spoils, salt water, and other residues and waste materials from the drilling, fracturing, or production of the well.
   (h)   Existing contours with intervals of not more than five feet where the slope is greater than ten percent, and not more than two feet where the slope is less than ten percent. However, one-foot contours are recommended and will be required in relatively flat topography. Elevations shall be based on sea level datum.
      (Ord. 0-24-98. Passed 4-20-98.)