(a) Site development plans shall be prepared by persons professionally qualified to do such work. Final site plans shall be certified by an architect, engineer, or land surveyor duly registered by the State of Ohio.
(b) Every site plan shall show the name of the development, the name and address of the owner and developer, north point, date, scale, and number of sheets.
(c) Site development plans shall be prepared at a scale of one-inch equals fifty feet or larger. No sheet shall exceed 42 inches in size. Seven copies shall be submitted to the Zoning Manager for plans which are to be reviewed by the Planning Commission.
(d) A site development plan may be prepared on one or more sheets to show clearly the information required by this section and to facilitate the review and approval of the plan. If prepared on more than one sheet, match lines shall clearly indicate where the several sheets join.
(e) Profiles must be submitted on standard plan profile sheets. Special studies as required may be submitted on standard cross section paper and shall have a scale of one (1) inch equals fifty (50) feet horizontally and one (1) inch equals five (5) feet vertically. No sheet size shall exceed 42 inches. Flood plain limit studies required by this Zoning Code shall be shown on all profile sheets with reference to properties affected and center line of stream.
(f) All horizontal distances shown on the site plan shall be in feet and decimals of a foot to the closest one-tenth of a foot; and all bearings in degrees to the nearest ten seconds.
(Ord. 71-18. Passed 11-26-18.)