1282.05 EXTERIOR LIGHTING PLAN.
   A lighting plan is required for all uses that are required to file a development plan and shall be approved according to the procedures set forth in Chapter 1246. All existing uses on which exterior lighting is installed or changed shall conform to these standards. The lighting plan shall demonstrate compliance with the exterior lighting standards of this chapter, and shall include the following items:
   (a)   A site plan showing location of all exterior light fixtures, controllers and transformers.
   (b)   Property boundaries, building location(s), parking lot layout, pedestrian paths, adjacent rights-of-way, north arrow and scale.
   (c)   Specifications and drawings or photographs for all exterior light fixture types, poles, conduit and appurtenant construction.
   (d)   Lamp wattage of all proposed luminaires.
   (e)   Information that indicates a minimum light level of one-half (0.5) foot-candles at grade in all vehicular use areas and connecting pedestrian paths.
   (f)   Cut sheets for all proposed exterior light fixtures and poles.
   (g)   Any other information and data reasonably necessary to evaluate the required lighting plan.
      (Ord. 8-13. Passed 5-14-13.)