1317.02 REGULATIONS.
   No principal residential structure shall be constructed, reconstructed, remodeled, located, erected, placed, enlarged or changed except in compliance with the following regulations prescribed herein:
   (a)   The water supply of the principal residential structure shall comply with all of the following requirements:
      (1)   The water line to the principal residential structure from the curbstop to the principal residential structure shall be constructed, maintained and repaired by the owner of the principal residential structure or the owner of the real estate, as the case may be, at his own expense; and
      (2)   The water line from the curbstop to the principal residential structure shall be SDR-9, 200 psi copper-sized tubing plastic pipe or its equivalent as to grade and quality; and
      (3)   The water line from the curbstop to the principal residential structure property shall be connected to the curbstop in a manner approved by the Cadiz Water Department or its designee.
   (b)   The sewage system of the principal residential structure shall comply with all of the following requirements:
      (1)   The sewer line to the principal residential structure from the sewer tap shall be constructed, maintained, and repaired by the owner of the principal residential structure or the owner of the real estate, as the case may be, at his sole expense; and
      (2)   The sewer line from the sewer tap to the principal residential structure shall be 4 inches in diameter or larger and shall be of SDR-35, schedule 40 plastic or its equivalent as to grade and quality; and
      (3)   The sewer line from the sewer tap shall be connected to the main sewer line in a manner approved by the Cadiz Water Department or its designee.
   (c)   All principal residential structures shall have an approved foundation, as defined in Section 1317.11 .
   (d)   The overall dimension of any side of a primary residential structure shall be not less than 24 lineal feet.
   (e)   The overall area of any lot upon which a principal residential structure is situated shall not be less than 5,000 square feet in area.
      (Ord. 93-11. Passed 3-18-93; Ord. 93-37. Passed 8-5-93.)