Skip to code content (skip section selection)
Compare to:
Boise Overview
Boise, ID Code of Ordinances
CITY CODE of BOISE CITY, IDAHO
ORDINANCES PENDING REVIEW FOR CODIFICATION
ADOPTING ORDINANCE
TITLE 1 ADMINISTRATION
TITLE 2 BOARDS, COMMISSIONS, COMMITTEES
TITLE 3 LICENSES AND PERMITS
TITLE 4 HEALTH AND SANITATION
TITLE 5 PUBLIC SAFETY
TITLE 6 MOTOR VEHICLES AND TRAFFIC
TITLE 7 PUBLIC WAYS AND PROPERTY
TITLE 8 AIRPORT
TITLE 9 BUILDING CODES AND REGULATIONS
CHAPTER 1 BUILDING CODE
CHAPTER 2 DEVELOPMENT IMPACT FEE
CHAPTER 3 SPECIAL DESIGN STANDARDS FOR TYPE V CONSTRUCTION
CHAPTER 4 PLUMBING CODE
CHAPTER 5 ELECTRICAL CODE
CHAPTER 6 UNIFORM HOUSING CODE
CHAPTER 7 MECHANICAL, FUEL GAS AND RESIDENTIAL CODES1
CHAPTER 7A MECHANICAL CODE
CHAPTER 7B FUEL GAS CODE
CHAPTER 8 SOLID FUEL HEATING APPLIANCES
CHAPTER 9 ENERGY CONSERVATION CODE
9-9-1: PURPOSE:
9-9-2: CODE ADOPTED:
9-9-3: IECC ENERGY CODE AMENDMENT, SECTION C101.1, TITLE:
9-9-4: IECC ENERGY CODE AMENDMENT, ADD SECTION C101.5.2, INDUSTRIAL, ELECTRONIC, AND MANUFACTURING EQUIPMENT:
9-9-5: IECC ENERGY CODE AMENDMENT, SECTION C104.2, SCHEDULE OF PERMIT FEES:
9-9-6: IECC ENERGY CODE AMENDMENT, SECTION C104.5, REFUNDS:
9-9-7: IECC ENERGY CODE AMENDMENT, SECTION C108, STOP WORK ORDER:
9-9-8: IECC ENERGY CODE AMENDMENT, SECTION C109, BOARD OF APPEALS PROCESS:
9-9-9: IECC ENERGY CODE AMENDMENT, ADD SECTION C110, VIOLATIONS:
9-9-10: IECC ENERGY CODE AMENDMENT, SECTION C201.3, TERMS DEFINED IN OTHER CODES:
9-9-11: IECC ENERGY CODE AMENDMENT, SECTION C202, GENERAL DEFINITIONS, CODE OFFICIAL:
9-9-12: IECC ENERGY CODE AMENDMENT, SECTION C402.5, AIR LEAKAGE-THERMAL ENVELOPE (MANDATORY), ADD EXCEPTION:
9-9-13: IECC ENERGY CODE AMENDMENT, SECTION C403.5, ECONOMIZERS (PRESCRIPTIVE), ADD EXCEPTION 7:
9-9-14: IECC ENERGY CODE AMENDMENT, TABLE C404.5.1, PIPING VOLUME AND MAXIMUM PIPING LENGTHS:
9-9-15: IECC ENERGY CODE AMENDMENT, SECTION R101.1, TITLE:
9-9-16: IECC ENERGY CODE AMENDMENT, SECTION R104.2, SCHEDULE OF PERMIT FEES:
9-9-17: IECC ENERGY CODE AMENDMENT, SECTION R104.5, REFUNDS:
9-9-18: IECC ENERGY CODE AMENDMENT, SECTION R108, STOP WORK ORDER:
9-9-19: IECC ENERGY CODE AMENDMENT, SECTION R109, BOARD OF APPEALS PROCESS:
9-9-20: IECC ENERGY CODE AMENDMENT, ADD SECTION R110, VIOLATIONS:
9-9-21: IECC ENERGY CODE AMENDMENT, SECTION R201.3, TERMS DEFINED IN OTHER CODES:
9-9-22: IECC ENERGY CODE AMENDMENT, SECTION R202, GENERAL DEFINITIONS, CODE OFFICIAL:
9-9-23: IECC ENERGY CODE AMENDMENT, TABLE R402.1.2, INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT:
9-9-24: IECC ENERGY CODE AMENDMENT, TABLE R402.1.2, INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT, ADD FOOTNOTES J AND K:
9-9-25: IECC ENERGY CODE AMENDMENT, TABLE R402.1.4, EQUIVALENT U-FACTORS:
9-9-26: IECC ENERGY CODE AMENDMENT, SECTION R402.4.1.2, TESTING:
9-9-27: IECC ENERGY CODE AMENDMENT, ADD SECTION R402.6, RESIDENTIAL LOG HOME THERMAL ENVELOPE:
9-9-28: IECC ENERGY CODE AMENDMENT, ADD TABLE R402.6, LOG HOME PRESCRIPTIVE THERMAL ENVELOPE REQUIREMENTS BY COMPONENT:
9-9-29: IECC ENERGY CODE AMENDMENT, SECTION R403.3.1, DUCT INSULATION REQUIREMENTS:
9-9-30: IECC ENERGY CODE AMENDMENT, DELETE SECTION R403.3.6, DUCTS BURIED WITHIN CEILING INSULATION:
9-9-31: IECC ENERGY CODE AMENDMENT, DELETE SECTION R403.3.7, DUCTS LOCATED IN CONDITIONED SPACE:
9-9-32: IECC ENERGY CODE AMENDMENT, SECTION R403.5.3, HOT WATER PIPE INSULATION (PRESCRIPTIVE):
9-9-33: IECC ENERGY CODE AMENDMENT, SECTION R404.1, LIGHTING EQUIPMENT (MANDATORY):
9-9-34: IECC ENERGY CODE AMENDMENT, SECTION R406.3, ENERGY RATING INDEX:
9-9-35: IECC ENERGY CODE AMENDMENT, TABLE R406.4, MAXIMUM ENERGY RATING INDEX:
CHAPTER 10 EXISTING BUILDING CODE
CHAPTER 11 DANGEROUS BUILDINGS CODE
CHAPTER 12 MOVING, DECONSTRUCTION, OR DEMOLITION OF BUILDINGS
CHAPTER 13 GREEN CONSTRUCTION CODE
CHAPTER 14 CONSTRUCTION SITE EROSION CONTROL
TITLE 10 PUBLIC UTILITIES
TITLE 11 DEVELOPMENT CODE
PARALLEL REFERENCES
CHAPTER 9
ENERGY CONSERVATION CODE
SECTION:
9-9-1: Purpose
9-9-2: Code Adopted
9-9-3: IECC Energy Code Amendment, Section C101.1, Title
9-9-4: IECC Energy Code Amendment, Add Section C101.5.2, Industrial, Electronic, And Manufacturing Equipment
9-9-5: IECC Energy Code Amendment, Section C104.2, Schedule Of Permit Fees
9-9-6: IECC Energy Code Amendment, Section C104.5, Refunds
9-9-7: IECC Energy Code Amendment, Section C108, Stop Work Order
9-9-8: IECC Energy Code Amendment, Section C109, Board Of Appeals Process
9-9-9: IECC Energy Code Amendment, Add Section C110, Violations
9-9-10: IECC Energy Code Amendment, Section C201.3, Terms Defined In Other Codes
9-9-11: IECC Energy Code Amendment, Section C202, General Definitions, Code Official
9-9-12: IECC Energy Code Amendment, Section C402.5, Air Leakage-Thermal Envelope (Mandatory), Add Exception
9-9-13: IECC Energy Code Amendment, Section C403.5, Economizers (Prescriptive), Add Exception 7
9-9-14: IECC Energy Code Amendment, Table C404.5.1, Piping Volume And Maximum Piping Lengths
9-9-15: IECC Energy Code Amendment, Section R101.1, Title
9-9-16: IECC Energy Code Amendment, Section R104.2, Schedule Of Permit Fees
9-9-17: IECC Energy Code Amendment, Section R104.5, Refunds
9-9-18: IECC Energy Code Amendment, Section R108, Stop Work Order
9-9-19: IECC Energy Code Amendment, Section R109, Board Of Appeals Process
9-9-20: IECC Energy Code Amendment, Add Section R110, Violations
9-9-21: IECC Energy Code Amendment, Section R201.3, Terms Defined In Other Codes
9-9-22: IECC Energy Code Amendment, Section R202, General Definitions, Code Official
9-9-23: IECC Energy Code Amendment, Table R402.1.2, Insulation And Fenestration Requirements By Component
9-9-24: IECC Energy Code Amendment, Table R402.1.2, Insulation And Fenestration Requirements By Component, Add Footnotes J And K
9-9-25: IECC Energy Code Amendment, Table R402.1.4, Equivalent U-Factors
9-9-26: IECC Energy Code Amendment, Section R402.4.1.2, Testing
9-9-27: IECC Energy Code Amendment, Add Section R402.6, Residential Log Home Thermal Envelope
9-9-28: IECC Energy Code Amendment, Add Table R402.6, Log Home Prescriptive Thermal Envelope Requirements By Component
9-9-29: IECC Energy Code Amendment, Section R403.3.1, Duct Insulation Requirements
9-9-30: IECC Energy Code Amendment, Delete Section R403.3.6, Ducts Buried Within Ceiling Insulation
9-9-31: IECC Energy Code Amendment, Delete Section R403.3.7, Ducts Located In Conditioned Space
9-9-32: IECC Energy Code Amendment, Section R403.5.3, Hot Water Pipe Insulation (Prescriptive)
9-9-33: IECC Energy Code Amendment, Section R404.1, Lighting Equipment (Mandatory)
9-9-34: IECC Energy Code Amendment, Section R406.3, Energy Rating Index
9-9-35: IECC Energy Code Amendment, Table R406.4, Maximum Energy Rating Index
9-9-1: PURPOSE:
The purpose of this Chapter is to establish minimum regulations for energy-efficient buildings using prescriptive, performance-based, or energy rating index compliance alternative provisions. The provisions of this code shall regulate the design and construction of building envelopes for adequate thermal resistance and low air leakage, including the design and selection of mechanical systems, service water-heating systems, pools and spas, electrical equipment, power, and lighting systems in order to enhance the efficient use and conservation of energy in new and existing building construction. (Ord. 43-17, 12-19-2017, eff. 1-1-2018; amd. Ord. 42-20, 12-1-2020, eff. 1-1-2021)
9-9-2: CODE ADOPTED:
All the rules, regulations, and ordinances relating and applying to the design, construction, quality of materials, erection, installation, alteration, repair, location, relocation, replacement, addition to, use or maintenance of the building envelope, building mechanical systems, service water-heating systems, pools and spas, electrical equipment, power, and lighting systems, established by the 2018 edition of the International Energy Conservation Code (IECC), published under the authority of the International Code Council, Inc., is hereby adopted as the Energy Conservation Code of Boise City as amended, and except to the extent that those said rules and regulations are hereby changed, altered, or amended by this code. One copy of the 2018 edition of the International Energy Conservation Code shall be filed for use and examination by the public in the Office of the City Clerk. All provisions in this Chapter shall be effective January 1, 2021. (Ord. 43-17, 12-19-2017, eff. 1-1-2018; amd. Ord. 42-20, 12-1-2020, eff. 1-1-2021)
9-9-3: IECC ENERGY CODE AMENDMENT, SECTION C101.1, TITLE:
   C101.1 Title. Boise City Code Title 9, Chapter 9 shall be known as the Energy Conservation Code of Boise City, and hereinafter may be cited or referred to as "this Chapter" and "this code."
(Ord. 43-17, 12-19-2017, eff. 1-1-2018; amd. Ord. 42-20, 12-1-2020, eff. 1-1-2021)
9-9-4: IECC ENERGY CODE AMENDMENT, ADD SECTION C101.5.2, INDUSTRIAL, ELECTRONIC, AND MANUFACTURING EQUIPMENT:
   C101.5.2 Industrial, electronic and manufacturing equipment. Buildings or portions thereof that are heated or cooled exclusively to maintain a required operating temperature for industrial, electronic, or manufacturing equipment shall be exempt from the provisions of this code. Such buildings or portions thereof shall be separated from connected conditioned space by building thermal envelope assemblies that comply with this code. If this condition or use is abandoned, then that building or portion thereof shall be subject to the requirements of this code.
(Ord. 43-17, 12-19-2017, eff. 1-1-2018; amd. Ord. 42-20, 12-1-2020, eff. 1-1-2021)
9-9-5: IECC ENERGY CODE AMENDMENT, SECTION C104.2, SCHEDULE OF PERMIT FEES:
   C104.2 Schedule of permit fees. The fees for residential energy code inspection(s), when applicable under the commercial provisions, reinspections, after hours inspections, or additional plan review after the third review or for modification changes, additions, or revisions after permit issuance, verifying compliance with the Energy Conservation Code of Boise City, shall be assessed in accordance with the provisions of the Boise City Building Code Fee Schedule as adopted by the City Council, which will be kept on file at the Planning and Development Services permit counter, Boise City Clerk's office, or on the Planning and Development Services website. All fees shall be reviewed by the Building Code Board prior to adoption by City Council.
(Ord. 43-17, 12-19-2017, eff. 1-1-2018; amd. Ord. 42-20, 12-1-2020, eff. 1-1-2021)
9-9-6: IECC ENERGY CODE AMENDMENT, SECTION C104.5, REFUNDS:
   C104.5 Refunds. Any fee refunds shall comply with the provisions of Section 109.6 of the International Building Code as adopted by the Building Code of Boise City or Section R108.5 of the International Residential Code as adopted by the One-And-Two-Family Dwelling Building Code of Boise City, as applicable.
(Ord. 42-20, 12-1-2020, eff. 1-1-2021)