Sec. 10-124.   Same--Construction requirements.
   Private accesses shall be constructed in accordance with the following standards and any permit therefor shall require conformity to the following:
   (1)   Width shall be no more than 48 inches;
   (2)   Height above grade shall be at least 18 inches, but no more than 24 inches;
   (3)   Pilings shall be installed at least three feet deep, but no more than five feet in depth;
   (4)   Stairs shall be used only when necessary to protect the integrity of the dune system and shall be allowed in the discretion of the building inspector for such purpose only;
   (5)   Construction of any private access shall be in accordance with the state building code;
   (6)   Handrails on any private access shall be prohibited unless otherwise required by the state building code;
   (7)   Permitted private accesses shall be constructed to follow the natural contour of the frontal dune; and
   (8)   Private accesses shall be permitted only from waterfront properties.
(Ord. No. 2001-047, § 4, 10-27-2001)