§ 51.063  CONNECTION OF BUILDING SEWER WITH PUBLIC SEWER.
   The connection of the building sewer into the public sewer shall be made by the city at the “Y” branch designated for that property, if such a branch is available at a suitable location. If the public sewer is 12 inches in diameter or less and no properly located UV branch is available, the city shall install a “Y” branch in the public sewer or make the connection with a saddle of approved type at a location approved by the Wastewater Superintendent. Where the public sewer is greater than 12 inches and no properly located “Y” branch is available, the city shall make the connection with a saddle specially designed for this application. All connections methods shall be approved by the Wastewater Superintendent. Manholes shall be constructed at any junction of an eight-inch diameter or larger sewer into a public sewer.
(Ord. 2009-02, passed 5-12-2009)