1341.29 ACCESSORY STRUCTURES.
   Relief to the elevation or dry floodproofing standards may be granted for accessory structures containing no more than 600 square feet. Such structures must meet the following standards:
   (a)    They shall not be used for human habitation;
   (b)    They shall be constructed of flood resistant materials;
   (c)    They shall be constructed and placed on the lot to offer the minimum resistance to the flow of floodwaters;
   (d)    They shall be firmly anchored to prevent flotation;
   (e)    Service facilities such as electrical and heating equipment shall be elevated or floodproofed to or above the level of the flood protection elevation; and
   (f)    They shall meet the opening requirements of Section 1341.27 (e)(3);
       (Ord. 2009-095. Passed 7-27-09.)