§ A23-5 MINIMUM AREA STANDARDS AND REQUIREMENTS.
   (A)   The following minimum area standards and requirements shall be met and no improvements shall be placed on such lands unless the lands to be used or improved shall meet the following area and dimensional requirements:
      (1)   Table of minimum area requirements and standards. The dimensions shall be measured in feet unless otherwise specified.
Requirements
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
Zone 7
Requirements
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
Zone 7
Minimum Lot Dimensions
 
 
 
Lot area (square feet)
Interior
11,000
15,000
(7,500)
10,000
Corner
12,500
Lot width
Interior
80
100
(50/unit)
80
Corner
90
Dwelling Unit Density
 
 
 
One-story building
7,260(6)
3,960(11)
3,068 (14)
Two-story building
7,260(6)
3,960(11)
3,068 (14)
Three-story building
2,178 (20)
Minimum Building Setback
 
 
 
Along principal or arterial streets
50
50
50
40
50
50
50
Along community collector streets
40
40
40
40
40
40
Along neighborhood collector streets
30
30
30
30
40
40
Along all other streets
30*
30
30
30
30
35
35
Along private streets
25
25
25
20
Side lot line
25
25
20
25
Dwelling
10
10
Garage
5
5
Rear lot line
30
30
25
25
25
25
Between multiple dwellings
**
**
**
**
Minimum Detached Garage and Accessory Building Setback
 
 
 
Along principal or arterial streets
50
50
50
50
50
Along community collector streets
40
40
40
40
40
40
Along neighborhood collector streets
30
30
30
30
40
40
Along all other streets
30*
30
30
30
35
30
Along private streets
10
10
20
20
Side lot line
5
5
10
10
10
10
Rear lot line
10
10
10
10
10
10
From multiple dwelling
15
15
15
15
From one-family dwelling
10
Abutting one-family detached lot
10
Minimum Parking Setback
 
 
 
Along all streets
20
20
20
20
20
Side or rear lot line
5
5
5
5
5
From multiple dwelling
10
10
10
10
Abutting one-family detached lot
Maximum Lot Coverage
 
 
 
 
 
 
 
Building coverage (percentage)
 
 
20
20
20
30
35
Impervious surface coverage
See §155.350
See §155.350
 
 
 
 
 
Maximum Building Coverage
 
 
 
Coverage of lot (percentage)
30
30
20
20
20
30
35
Maximum Building Height
 
 
 
Maximum height
35
35
35
35
40
35
35
NOTES TO TABLE
 * - Corner lot sideyard setbacks abutting a local street shall be 20 feet.
** - See § A23-5(B).
 
   (B)   Setbacks between multiple dwellings. For the purposes of this subsection, the term “side” shall refer to the short sides of a structure and the terms “front” or “rear” shall refer to the long sides of the structure.
      (1)   The front and rear sides of the multiple dwelling shall have a minimum setback of 50 feet from any side of an adjacent multiple dwelling or a setback equal to the combined height of the adjacent multiple dwellings, whichever is greater, except that in no case shall a setback greater than 75 feet be required. The minimum setback shall be reduced to 40 feet where a horizontal extension the lines created by the nearest exterior vertical surfaces of adjacent buildings would create an angle of not less than 45 degrees.
      (2)   Minimum setbacks between adjacent multiple buildings on sides of multiple- residential buildings shall be 15 feet or a distance equal to half the combined height of the adjacent building faces, whichever is greater.
   (C)   Maximum impervious surface, see § 155.350.
   (D)   Screening, see § 155.348.
   (E)   Landscaping, see § 155.349.
   (F)   Parking, see §§ 155.370 through 155.379.
(Ord. 632, passed 9-25-97; Am. Ord. 672, passed 5-11-00; Am. Ord. 674, passed 7-13-00; Am. Ord. 700, passed 9-25-01 ; Am. Ord. 1050, passed 10-11-18)