§ A16-5 MINIMUM AREA REQUIREMENTS.
   (A)   The following minimum area standards and requirements shall be met. No improvements shall be placed on such lands unless the lands to be so used or improved shall meet the following area and dimensional requirements:
      (1)   Table of minimum area requirements and standards. The dimensions shall be measured in feet unless otherwise specified.
   Minimum Lot Dimensions
   Lot area (square feet)   43,560
   Lot width    150
   Minimum Building Setback
   Along principal or arterial streets       40
   Along community collector    streets    40
   Along all other streets            30
   Side lot line    10
   Rear lot line    15
   Abutting one-family detached, duplex or multiple lot    50
   Minimum Parking Setback
   Along all other streets    20
   Side or rear lot line    5
   Abutting one-family detached,
   duplex or multiple lot    20
   Maximum Building Coverage
   Coverage of lot (%)    20
   Maximum Building Height
   Maximum height    35
      (2)   Maximum impervious surface, see § 155.350.
      (3)   Screening, see § 155.348.
      (4)   Landscaping, see § 155.349.
   (B)   The following requirements are in addition to those in division (A). Where there may be a conflict, the requirements herein shall prevail:
      (1)   Side and rear setbacks, party walls. Buildings may be excluded from side and rear setback requirements if party walls are used and if the adjacent buildings are constructed as an integral structure.
      (2)   Parking requirements. The minimum required number of parking stalls shall be computed based upon the most intensive use of the property as permitted under the terms of §§ A16-2(A) and A16-5(A). See also §§ 155.370 through 155.379 .
(‘81 Code, § A16-5) (Ord. 409, passed 1-14-88)