(A) The following minimum area standards and requirements shall be met. No improvements shall be placed on such lands unless the lands to be so used or improved shall meet the following area and dimensional requirements:
(1) Table of minimum area requirements and standards. The dimensions are measured in feet unless otherwise specified.
Requirements |
Zone 1
|
Zone 2
|
Zone 3
|
Requirements |
Zone 1
|
Zone 2
|
Zone 3
|
Minimum Lot Dimensions | |||
Lot area (square feet): | — | ||
Interior | 8,500 | 10,000 | |
Corner | 10,500 | — | |
Lot width | — | ||
Interior | 68 | 80 | |
Corner | 85 | — | |
Dwelling Unit Density4
| |||
One-story building | — | 7,2601
(6)2
| — |
Two- or three-story building | — | 3,630(12) | — |
Minimum Building Setback | |||
Along neighborhood collector streets | 30 | 40 | 40 |
Along other streets | 303
| 30 | 30 |
Side lot line | 25 | 20 | |
Dwelling | 10 | ||
Garage | 5 | ||
Rear lot line | 30 | 25 | 20 |
From multiple-dwelling | — | * | — |
Abutting one-family detached lot | — | 30 | — |
Minimum Detached Garage and Accessory Building Setback | |||
Along neighborhood collector streets | ** | 35 | — |
Along other streets | ** | 30 | — |
Side lot line | ** | 10 | — |
Rear lot line | ** | 10 | — |
From multiple dwelling | — | 15 | — |
Abutting one-family detached lot | — | 20 | — |
Minimum Parking Setback | |||
Along all streets | — | 15 | 20 |
Side or rear lot line | — | 5 | 10 |
From multiple dwelling | — | 10 | — |
Abutting one-family detached lot | — | 15 | — |
Maximum Lot Coverage | |||
Building coverage (percentage) | 25 | 20 | |
Impervious surface coverage | See § 155.350 | ||
Maximum Building Coverage | |||
Coverage of lot (percentage) | 20 | 20 | 20 |
Maximum Building Height | |||
Maximum height | 35 | 40 | 40 |
NOTES TO TABLE | |||
(2) Setbacks between multiple dwellings.
(a) The front and rear sides of a multiple dwelling shall have a minimum setback of 50 feet from any side of an adjacent multiple dwelling or a setback equal to the combined height of the adjacent multiple dwellings, whichever is greater, except that in no case shall a setback greater than 75 feet be required. This minimum setback shall be reduced to 40 feet where a horizontal extension of the lines created by the nearest exterior vertical surfaces of adjacent buildings would create an angle of not less than 45 degrees.
(b) Minimum setbacks between adjacent multiple dwellings on sides which are not a front or rear side of either building shall be 20 feet or a distance equal to half the combined height of the adjacent buildings, whichever is greater, except that in no case shall a setback greater than 50 feet be required. This minimum setback shall be reduced to 25 feet where a horizontal extension of the lines created by the nearest exterior vertical surfaces of adjacent buildings would create an angle of not less than 45 degrees.
(3) Maximum impervious surface, see § 155.350.
(4) Screening, see § 155.348.
(5) Landscaping, see § 155.349.
(B) The following requirements are in addition to those in division (A). Where there may be a conflict, the requirements herein shall prevail:
(1) Front setbacks prevailing. Where adjoining structures existing at the time of adoption of this article have a greater setback than that required by this article, the front setback of a new structure shall conform to the prevailing setback in the immediate vicinity. The Building Official shall determine the necessary front yard setback in such cases. In no case shall a building be required to be set back more than 50 feet.
(2) Side and rear setbacks, party walls. Buildings may be excluded from side and rear setback requirements if party walls are used and if the adjacent buildings are constructed as an integral structure. This shall not permit structures closer to single family detached or duplex lots, however, than required under division (A)(1) above.
(‘81 Code, § A14-5) (Ord. 342, passed 9-26-85
; Am. Ord. 1050, passed 10-11-18)