§ 10-2-11 PLAN AND PROFILE SHEETS.
   (A)   Plan and profile are required for the following construction plans:
      (1)   All arterial and secondary collector streets plus other streets when longitudinally matching existing streets;
      (2)   Water line plans within existing streets;
      (3)   Water line plans with pipe size 12 inches in diameter or greater;
      (4)   All storm drain pipe plans;
      (5)   All sewer line plans; and
      (6)   All effluent line plans.
   (B)   The following information is required:
      (1)   Plan view prepared in accordance with Apache Junction City Code Vol. II, § 10-2-10;
      (2)   Profile view to the scale noted in Apache Junction City Code Vol. II, § 10-2-5(D) depicting the following:
         (a)   Elevation and stationing grid;
         (b)   Profile of existing surface over proposed construction;
         (c)   Existing utility crossings; and
         (d)   Proposed construction (e.g., elevations, slopes and grade breaks).
      (3)   New construction notes shall be heavier (darker) than the general information notes so that they contrast; and
      (4)   Where the sanitary sewer is approved to be less than 5 feet deep, the proposed water line shall be indicated in profile by a “ghost” line, and the building sewers shall be plotted at the locations and inverts where they cross the water line. The MAG Standard Detail 404 shall be called out and shown, when needed, on both plan and profile.
   (C)   Double plan and profile shall only be permitted with written approval for the development services project engineer.
(Ord. passed - - )