§ 10-2-7 DETAIL SHEET.
   (A)   A separate detail sheet may be provided at the discretion of the consultant or when required by the city.
   (B)   The following information is required:
      (1)   Construction notes (Apache Junction City Code Vol. II, §§ 10-2-12 through 10-2-16);
      (2)   A typical cross-section for each street in the street construction plans. The information required on a typical section is:
         (a)   Dimensions;
         (b)   Street centerline and right-of-way line;
         (c)   MAG and Apache Junction Standard Details and Specifications;
         (d)   Pavement structural design;
         (e)   Trim and match to existing street; and
         (f)   Existing and proposed utilities.
      (3)   Special construction details as required shall be provided, to include:
         (a)   Modification or relocation detail for existing structures;
         (b)   Special construction required where utility locations conflict; and
         (c)   Others determined by the consultant and/or the city to clarify construction design as well as construction information.
   (C)   General plan information:
      (1)   Plan layout, graphics and call-outs must be clearly presented in an uncluttered manner acceptable to the development services project engineer;
      (2)   Call-out shall be boxed numeric style call-outs. Each number shall relate to the same topic for the entire set of plans. Narrative call-outs shall be grouped and clearly shown on every page that the call-out is used. Stationing and offset shall accompany every applicable call-out number;
      (3)   Plans may show only 1 utility (e.g., water, sewer, storm drain, grading and drainage, or paving) on the plans at a time, in bold, for review. All other infrastructure, existing and future, shall be shown lighter (smaller pen width or dashed). Exceptions to this are:
         (a)   Storm drain and paving may be on the same sheet (separate fees apply for each utility).
         (b)   Water and sewer may be on the same sheet (separate fees apply for each utility).
      (4)   Plans shall provide cross-referencing between all sheets which have details, detail call-outs, notes, and the like; and
      (5)   Plans shall be oriented with north at the top or right side of each sheet whenever possible. A north arrow and bar scale shall be provided.
(Ord. passed - - )