§ 18-9-403. Bulk regulations.
   Except as provided otherwise in this article, the following bulk regulations are applicable in a Small Business District:
Minimum lot size:
   If not served by public sewer
20,000 square feet
   If served by public sewer
11,000 square feet
Maximum coverage by all structures
50% of gross area
Minimum setbacks for principal structures:
   Front lot line
20 feet
   Side lot line
7 feet
   Corner side lot line
15 feet
   Rear lot line
20 feet
   Principal arterial or higher classification road
40 feet
Front and side setbacks on properties adjacent to developed lots
The lesser of the setback required by this section or a setback equal to the average of the setbacks of existing principal structures on abutting lots, except that if only one abutting lot is improved, the required setback shall be determined by averaging the setback on the improved lot and the setback required under this section.
Minimum setbacks for accessory structures:
   Front lot line
30 feet
   Side lot line, rear lot line
7 feet
   Corner side lot line
15 feet
Maximum height limitations:
   Principal structure
40 feet
   Accessory structure
30 feet
Maximum floor area for structures on properties with frontage on a minor arterial road or higher:
   Principal structures
10,000 square feet
   Principal structures – religious facilities
15,000 square feet
   Accessory structures
3,000 square feet
Maximum floor area for all other structures:
   Principal structures
5,000 square feet
   Accessory structures
2,000 square feet
 
(Bill No. 4-05; Bill No. 7-10; Bill No. 92-23 ; Bill No. 14-24)