§ 23.12.080 HEIGHT EXCEPTIONS.
   The structures listed in the following table may exceed the maximum permitted building height for the zoning district in which they are located, subject to the limitations stated and further provided that no portion of a structure in excess of the building height limit may contain habitable areas or advertising.
TABLE 23.12.080: ALLOWED PROJECTIONS ABOVE HEIGHT LIMITS
Allowed Projection
Maximum Vertical Projection Above the Height Limit
Maximum Coverage and Locational Limitations
TABLE 23.12.080: ALLOWED PROJECTIONS ABOVE HEIGHT LIMITS
Allowed Projection
Maximum Vertical Projection Above the Height Limit
Maximum Coverage and Locational Limitations
Skylights
1 foot
None
Chimneys
8 feet
None
Flagpoles
15 feet
None
Decorative features such as spires, cupolas, bell towers, domes, obelisks, and monuments
 
Rooftop open space features such as sun decks, sunshade and windscreen devices, open trellises, and landscaping
 
 
 
10 feet
 
 
 
Limited to a total of 20% of roof area, inclusive of all structures
Elevator and stair towers
Minimum amount necessary to comply with Building Code standards, up to a maximum of 15 feet
Limited to a total of 10% of roof area
 
Shall be appropriate in scale, intensity, and height
 
Must be setback from the exterior wall one foot for every foot of projection above the height limit
Mechanical equipment penthouses
10 feet
Limited to 60% of roof area
 
Must be setback from the exterior wall one foot for every foot of projection above the height limit
Mechanical equipment
5 feet
Must be setback from the exterior wall one foot for every foot of projection above the height limit
Fire escapes, catwalks, and open railings required by law
No restriction
None
Telecommunications facilities, antennas, microwave equipment, and radio towers
Subject to the provisions of § 23.22.240
 
(Ord. 4823, passed 1-22-24)