§ 53.04 CONNECTION TO PUBLIC SEWER.
   (A)   No unauthorized person shall uncover, make any connections with or opening into, alter or disturb any public sewer or appurtenance thereof without first obtaining a written permit from the Clerk-Treasurer and signed by the Wastewater Superintendent.
   (B)   (1)   There shall be two classes of building sewer permits:
         (a)   For residential and commercial service; and
         (b)   For service to establishments producing industrial wastes.
      (2)   In either case, the owner or his or her agent shall make application on a special form furnished by the town. The permit application shall be supplemented by any plans, specifications or other information considered pertinent in the judgment of the Inspector. A permit and inspection fee of $25 for a residential or commercial building sewer permit and $50 for an industrial building sewer permit shall be paid to the Clerk-Treasurer at the time the application is filed.
   (C)   All costs and expenses incident to the installation and connection of the building sewer shall be borne by the owner. The owner shall indemnify the town from any loss or damage that may directly or indirectly be occasioned by the installation of the building sewer.
   (D)   A separate and independent building sewer shall be provided for every building; except where one building stands at the rear of another on an interior lot and no private sewer is available or can be constructed to the rear building through an adjoining alley, court yard or driveway, the building sewer from the front building may be extended to the rear building and the whole considered as one building sewer.
   (E)   Old building sewers may be used in connection with new buildings only when they are found, on examination and test by the Inspector, to meet all requirements of this chapter.
   (F)   The building sewer shall be no less than six inches in diameter, sloped not less than one-eighth inch per foot and the material shall be SDR 35 PVC or other suitable material approved by the Wastewater Superintendent. The pipe shall be bedded six inches below and to the top of the pipe with crushed stone. Where a wye is not available, a wye or saddle shall be installed for a connection.
   (G)   Whenever possible, the building sewer shall be brought to the building at an elevation below the basement floor. In all buildings in which any building drain is too low to permit gravity flow to the public sewer, sanitary sewage carried by such building drain shall be lifted by an approved means and discharged to the building sewer.
   (H)   No person shall make connection of inflow sources such as roof downspouts, exterior foundation drains, areaway drains or other source of surface run-off or ground water to a building sewer or building drain which in turn is connected directly or indirectly to a public sanitary sewer.
   (I)   Unpolluted water from air conditioners, cooling, condensing systems or swimming pools shall be discharged to a storm sewer, where it is available. Where a storm sewer is not available, discharge may be to a natural outlet approved by the town and by the State of Indiana. Where a storm sewer is not available, such unpolluted water may be discharged to a sanitary sewer pending written approval by the town.
   (J)   The inflow/clear water connection for any new building shall be made separate and distinct from the sanitary waste connection to facilitate disconnection of the former if a separate storm sewer subsequently becomes available.
   (K)   The connection of the building sewer into the public sewer shall conform to the requirements of the Building and Plumbing Code or other applicable rules and regulations of the town or the procedures set forth in appropriate specifications of the A.S.T.M. and the W.P.C.P. Manual of Practice NO. 9. All such connections shall be made gas-tight and water-tight. Any deviation from the prescribed procedures and materials must be approved by the Wastewater Superintendent before installations.
   (L)   The size, slope, alignment, materials of construction of a building sewer and the methods to be used in excavating, placing of the pipe, jointly testing and backfilling the trench, shall all conform to the requirements of the Building and Plumbing Code or other applicable rules of the town. In the absence of code provisions or in amplification thereof, the materials and procedures set forth in appropriate specifications of the ASTM and WPCF Manuals of Practice No. 9 shall apply.
   (M)   The applicant for the building sewer permit shall notify the Inspector when the building sewer is ready for inspection and connection to the public sewer. The connection shall be made under the supervision of the Inspector or his or her representative.
   (N)   All excavations for building sewer installation shall be adequately guarded with barricades and lights so as to protect the public from hazard. Streets, sidewalks, parkways and other public property disturbed in the course of the work shall be restored in a manner satisfactory to the town.
   (O)   No user shall make a new connection unless there is capacity available to all downstream sewers, lift stations, force mains and the sewage treatment plant, including capacity for compatible pollutants.
   (P)   Except as otherwise provided, it shall be unlawful to construct or maintain any privy, privy vault, septic tank, cesspool, or other facility intended or used for the disposal of sewage.
   (Q)   The owner of all homes, buildings, or properties used for human occupancy, employment, recreation or other purposes, situation with the town and abutting on any street, alley or right- of-way in which there is now located a public sanitary sewer of the town is hereby required at his or her expense to install suitable toilet facilities therein, and to connect such facilities directly with the proper public sewer in accordance with the provisions of this chapter, within 90 days after date of official notice to do so, provided that said public sewer is within 300 feet of the property line.
   (R)   No unauthorized person shall uncover, make any connections with or opening into, use, alter or disturb any public sewer or appurtenance thereof without first obtaining a written permit from the Clerk-Treasurer.
   (S)   No unauthorized person shall maliciously, willfully or negligently break, damage, uncover, deface or tamper with any structure, appurtenance or equipment which is a part of the POTW. Any person violating this provision shall be subject to immediate arrest under charge of disorderly conduct.
(Ord. 2019-5, passed 4-22-19)