(a) Light Standards. The installation of street lighting is the responsibility of the developer. In conjunction with the electric utility company, the developer shall select lighting standards and fixtures which maintain the following minimum lighting standards:
Type of Area | Foot Cande Average |
Residential | .5 |
Industrial and/or commercial | .9 1/2 |
Shpping areas and centers | 5 - 10 |
(b) Height. All lighting fixtures shall be designed and located for the use intended. Light sources shall meet the following minimum height requirements.
Location | Minimum Feet Above Grade |
Pedestrian walkways | 12 |
Parking lots | 15 |
Streets | 25 |
(c) Glare. The shielding of lighting standards shall provide proper lighting without hazards for drivers or nuisances to residents. All site and parking lot lighting shall be directed on- site.
(d) Design. The design of lighting standards shall be of a type appropriate to the development.
(e) Electrical Feeds. Electrical feeds for lighting shall be run underground, not overhead.
(f) Planning Commission Review. These standards shall be the minimum standards unless the Planning Commission review determines otherwise.
(Ord. 21-98. Passed 12-1-98.)