1048.03 CONSTRUCTION OF HOUSE SEWER AND CONNECTIONS.
   The house sewer and connection to a public sewer shall be constructed as follows: The house sewer shall be of the best quality salt-glazed hub and spigot vitrified sewer pipe, not less than four inches in internal diameter, and shall be laid in open trench. The joints shall be made watertight by a method approved by the Village Manager. In order to permit ventilation of the public sewer and house sewer, no trap shall be placed in the house sewer. After the sewer is laid and before it is covered or used, it shall be inspected and approved by the Village Manager.
(Ord. 1955-1. Passed 9-19-55.)