§ 1442.07 HANGING FIXTURES AND SIGNS; CORRIDORS AND ROOM IDENTIFICATION.
   (a)   Light fixtures, protruding signs and similar hanging objects or signs and fixtures shall not be lower than six feet, eight inches above the floor.
   (b)   Corridors shall conform to applicable chapters of the Ohio Building Code, but shall be not less than four feet in width and shall have a minimum area of five feet by five feet at the end thereof to permit turning a wheelchair around. There shall be not more than 40 feet between the five feet by five feet areas.
   (c)   Room identification plates made of metal, plastic or other suitable material, with a minimum one-inch high raised or incised letters or numbers, shall be affixed to the wall surface approximately five feet above the floors, in a horizontal line, adjacent to the latch side of a door. Doors leading to dangerous areas, such as fire escapes, loading platforms, switch rooms, street exits and mechanical rooms, shall be equipped with knobs, handles or push bars that have a knurled or an approved abrasive tape surface.
(Ord. 74-75, passed 7-25-1974)