Section 155.9.10 Private Piers and Docks Including Residential.
   (A)   All lighting fixtures must meet the following standards:
      (1)   Fixtures must be full cut-off or shielded and properly aimed so that they control glare, do not produce up-lighting, and contain light to prevent trespass on adjoining uplands, public rights-of-way and public trust waters.
      (2)   Disabling glare that impairs the ability of boaters to safely traverse public trust waters shall be prohibited.
      (3)   Mounting height shall be as low as practicable but in no case shall the fixture be mounted higher than 25 feet above the lowest platform of the dock or pier.
      (4)   Bare light sources (including but not limited to festive light strands, incandescent, fluorescent, high intensity discharge, and neon) used to outline private piers and docks are prohibited.
   (B)   Standard. All illumination of parking lots, outdoor storage and display areas and commercial driveways shall comply with the intensities and uniformity ratios in Section 155.9.14 or by the standard within this section whichever is the more stringent.
(Ord. 1695, passed 11-8-12; Am. Ord. 1838, passed 3-10-22)