The conceptual utility drawings shall contain the following information:
(a) The pipe size, shape, manholes and location of the sanitary sewer system;
(b) The size, shape and slope for all pipes and channels of the storm sewer system with accompanying storm drainage calculations;
(c) The size and location of water lines and fire hydrants; and
(d) Street grades, cross sections, elevations and contours at two foot intervals.
(Ord. 12-2008. Passed 4-7-08.)