(a) The maximum diameter of any earth station shall not exceed twelve feet.
(b) Only metal support construction shall be permissible.
(c) The structure must be in conformance with the National Electric Code, Article 800 and related articles as referenced.
(d) Only a concrete base shall be employed in line with grade.
(e) The maximum height of any earth station shall be sixteen feet from grade level.
(f) The structure, including foundation, shall be designed to withstand wind force of up to seventy miles per hour in conformance with generally accepted engineering practices.
(g) Any driving motor shall be limited to 110 volt maximum power design, be encased in protective guards and be in compliance with requirements as provided in the National Electric Code, Article 800.
(h) All underground electrical wiring shall be encase in approved PVC conduit or rigid conduit with an eight inch cover, and overhead wiring shall also meet the approval of the Building Code and comply with the requirements as provided in the National Electric Code, Article 800 and subsequent articles.
(i) The earth station shall be bonded to an eight foot grounding rod and in accordance with the requirements as provided in the National Electric Code.
(j) Should guy wires be used, they shall be confined within a fenced area or be protected by a suitable shield.
(Ord. 1500. Passed 12-14-99.)
CODIFIED ORDINANCES OF WINDHAM