(A) (1) Information required at the time of application (one copy of each):
(a) Completed application and fees; and
(b) Proof of ownership (title policy) and owner’s written authorization.
(2) Information required directly on plans (25 copies of each to be submitted with application - sheet size shall be no less than eight and one-half inches by 11 inches and no more than 30 inches by 36 inches):
(a) Date, north arrow and engineer’s scale, one inch equals 200 feet or larger;
(b) Name of project;
(c) Property address or location;
(d) Legal description complete;
(e) Registered surveyor’s name and address;
(f) Total acreage;
(h) Zoning on and adjacent to site;
(i) Names and dimensions of adjacent streets;
(j) Dimensions and square footage of each lot;
(k) Lot and block numbers;
(l) Proposed street names;
(m) Bearing, distances, chords, radii, central angles, tangent lines and the like for all lots, blocks, perimeter and rights-of-way;
(n) Existing/proposed adjacent street improvements showing pavement widths and intersecting streets;
(o) Existing/proposed rights-of-way in and adjacent;
(p) Location and widths of sidewalks;
(q) Existing/proposed easements in and adjacent;
(r) Existing/proposed utility lines (including fire hydrants) and sizes in and adjacent;
(s) Existing/proposed curb cuts in and adjacent;
(t) Existing/proposed waterways and ditches in and adjacent;
(u) Existing/proposed floodplain lines on and adjacent;
(v) A statement: all, part or none of the property is in the floodplain;
(w) Existing/proposed structures and paved areas on the site;
(x) Proposed heights of all structures;
(y) All public sites to be reserved or dedicated (parks, streets and the like);
(z) Landscape plan;
(aa) Percentage of land devoted to buildings, parking and drives, sidewalks and landscaping in table form;
(bb) Number of employees for non-residential uses and required parking spaces; and
(cc) Latitude, longitude and elevation on property corners.
(3) Information required for review-to be submitted with application (one copy of each, except as noted):
(a) Boundary closure;
(b) Letter from County Treasurer verifying payment of taxes; and
(c) Soil report sealed by a registered engineer (three copies).
(4) Additional information required prior to recording (one copy of each to be submitted to Planning and Zoning Official after final City Council approval):
(a) Final street plans and profiles stamped by a registered engineer;
(b) Final drainage plan stamped by a registered engineer;
(c) Final utility plan stamped by a registered engineer;
(d) Final landscaping plan; and
(e) Financial security agreements.
(Prior Code, § 10-3.06)
(B) (1) Information required at the time of application (one copy of each):
(a) Completed application and fees; and
(b) Proof of ownership (title policy) and owner’s written authorization.
(2) Information required directly on plans (25 copies of each to be submitted with application - sheet size shall be no less than eight and one-half inches by 11 inches and no more than 30 inches by 36 inches):
(a) Date, north arrow and engineer’s scale, one inch equals 200 feet or larger;
(b) Name of project;
(c) Property address or location;
(d) Vicinity map at one-half mile radius;
(e) Legal description complete;
(f) Registered surveyor’s name and address;
(g) Total acreage;
(h) Zoning on and adjacent to site;
(i) Names and dimensions of adjacent streets;
(j) Lot and block numbers;
(k) Proposed street names;
(l) Existing/proposed adjacent street improvements showing pavement widths and intersecting streets;
(m) Existing/proposed rights-of-way in and adjacent;
(n) Location and widths of sidewalks;
(o) Existing/proposed easements in and adjacent;
(p) Existing/proposed utility lines (including fire hydrants) and sizes in and adjacent;
(q) Existing/proposed curb cuts in and adjacent;
(r) Existing/proposed waterways and ditches in and adjacent;
(s) Topography acceptable to the City Engineer;
(t) Statement on how drainage will be handled;
(u) Existing/proposed floodplain lines on and adjacent;
(v) A statement: all, part or none of the property is in the floodplain;
(w) Existing/proposed structures and paved areas on the site;
(x) Proposed heights of all structures;
(y) All public sites to be reserved or dedicated (parks, streets and the like);
(z) Landscape plan;
(aa) Percentage of land devoted to buildings, parking and drives, sidewalks and landscaping in table form;
(bb) Number of employees for non-residential uses and required parking spaces;
(cc) Proposed use of site;
(dd) Gross and net residential densities of each parcel;
(ee) Latitude, longitude and elevation of property corners; and
(ff) Phasing plan.
(3) Information required for review-to be submitted with application (one copy of each, except as noted):
(a) Capacity and need for water and for sewer;
(b) Stamped, addressed envelopes for all property owners within 300 feet of proposed development;
(c) Construction schedule;
(d) Protective covenants if proposed;
(e) Traffic impact analysis (three copies);
(f) Drainage report (three copies); and
(g) Water agreement (three copies).
(Prior Code, § 10-3.07)