1391.10  SANITARY SEWERS.
   (a)   Installation.  Installation of sanitary sewers and appurtenances shall be in accordance with the rules and regulations of the White Oak Borough Authority or its assigns.  All installations, including house connections, shall be made prior to the paving of the street and shall be thoroughly tamped.
 
   (b)   Minimum Size and Grade. The minimum diameter of sanitary sewers shall be eight inches and the minimum grade shall be 0.5 percent (0.5%).
 
   (c)   Laterals.  Lateral connections, where required, shall be installed to the right-of-way line of the street prior to road paving.  Each building shall have a separate connection to the Borough sewer, except that garages accessory to dwellings may be connected to the dwelling line. 
(Ord. 2748.  Passed 11-17-86.)