§ 153.65 PLANS AND SPECIFICATIONS.
   (A)   Prior to the construction of any streets and utilities, the developer shall furnish three complete sets of plans and specifications for said construction to the Plat Officer. These documents shall be transmitted in writing.
      (1)   These plans and specifications will be reviewed for conformity with this chapter and the city standards. The plans and specifications shall be approved in writing prior to any construction. The city appointed engineer shall approve the plan prior to the time the Planning Commission recommends approval of preliminary plat. Cost of engineering and inspections, to be determined on the basis of time devoted to the project at city wage scale, shall be charged to the developer.
      (2)   The Plat Officer shall be notified prior to the beginning of construction so that inspection of work can be made by the appropriate appointed city official.
   (B)   The plans shall be securely bound and shall consist of a title sheet and such plan-profile and detail sheets as are required to meet the requirements of this chapter and to properly define the proposed work.
      (1)   The title sheet shall show the name of the subdivision, engineer, date, and an index of drawings.
      (2)   Each plan-profile will generally be drawn to a horizontal scale of no greater than one inch to 100 feet and a vertical scale of one inch to ten feet.
   (C)   There shall be a plan-profile for typical streets and alleys. The profile shall show the existing ground on each side of the street at the property line, the proposed grade of the top of the curb for each side of the street, location of utilities, and other information necessary to define the work.
   (D)   The plans shall show all information necessary to locate and construct the proposed work and shall show the locations of all manholes, inlets, and other appurtenances of the system.
      (1)   The profile shall show the existing natural ground at the sewer centerline and the proposed grade at the centerline if such grade will not be the same as the existing grade.
      (2)   The size, grade, and material of the proposed pipes and the flow lines of all manholes, inlets, etc., shall be shown. Both the flowline and the inside top of the pipes shall be shown in the profile.
      (3)   These plans shall be accompanied by the engineer's calculations when requested by the City Engineer.
   (E)   The specifications shall be securely bound and shall consist of the following minimum information: general conditions of agreement, special conditions of agreement, and all applicable technical specifications. The special conditions shall contain provisions for time of completion, performance, and payment bonds, and other pertinent requirements.
(Ord. 172, passed 6-8-87)