11-3-36: MANUFACTURED HOME PARK STANDARDS:
   A.   Lot Requirements:
      1.   All lots for manufactured home spaces in a manufactured home park shall meet the following requirements:
         a.   Manufactured home lots shall be arranged to permit the safe and practical placement and removal of manufactured homes.
         b.   The minimum lot width shall not be less than fifty feet (50').
   B.   Minimum Standards:
      1.   Setbacks From Boundaries: All manufactured homes shall be located at least twenty five feet (25') from any property boundary line abutting upon a public street or highway right-of- way and at least fifteen feet (15') from the other outer boundaries of the park.
      2.   Setbacks From Streets: All buildings, structures and manufactured homes shall be located at least ten feet (10') from the street providing access to it.
      3.   Distance Between Manufactured Homes: Neither manufactured home nor its attached structures, such as awnings or carports, shall be located within twenty feet (20') of any other manufactured home or its attached structures.
      4.   Detached Accessory Structures: No detached structure, such as a storage shed, shall be located within five feet (5') of any manufactured home or its attached structures.
      5.   Lot Coverage: A manufactured home shall not occupy more than one-third (1/3) of the lot area. The total area occupied by a manufactured home and its roofed accessory buildings and structures shall not exceed two-thirds (2/3) of the area of the lot.
      6.   Parking Spaces Required: A minimum of two (2) parking spaces shall be provided for each manufactured home lot. In addition, guest parking at the ratio of one space for each five (5) lots and vehicle storage parking at the ratio of one space per each ten (10) lots shall be provided. Parking dimensions shall meet the zoning standards for parking.
   C.   Marking Of Manufactured Home Lots: The limits of each manufactured home lot shall be clearly marked on the ground by permanent flush stakes, markers or other suitable means. Location of lot limits on the ground shall be the same as shown on the approved plans.
   D.   Manufactured Homes To Be Skirted: Each manufactured home shall be skirted within sixty (60) days after it is moved upon a lot within the manufactured home park. Said skirting shall be of a fire resistant material complementary to that of which the manufactured home exterior is constructed and shall be attached to the manufactured home.
   E.   Electrical Systems: All electrical lines serving the subdivision shall be buried underground and shall be designed and constructed in accordance to the most recent edition of the national electrical code.
   F.   Oil Or Propane Gas Heating: Where oil or propane gas heating of a manufactured home is necessary, a fuel storage facility shall be provided on the manufactured home site not to exceed a three hundred (300) gallon capacity. Said storage facility shall extend no higher than six feet (6') above ground level and shall be located and screened so it will blend with its surroundings.
   G.   Gas Systems: All gas systems serving the subdivision shall be designed and constructed in accordance to the most recent edition of the national fuel gas code, the standard for the storage and handling of liquefied petroleum gases and the fire code.
      1.   A readily accessible and identifiable shutoff valve controlling the flow of gas to the entire gas piping system shall be installed near the point of connection of the liquefied petroleum gas container.
      2.   Each manufactured home lot shall have an accessible, listed gas shutoff installed. Said valve shall not be located under a manufactured home. Whenever a manufactured home lot outlet is not in use, the shutoff valve shall be plugged to prevent accidental discharge. (Ord. 13-06, 10-7-2013)