(A) The following minimum requirements shall be observed subject to additional requirements, exceptions and modifications as set forth elsewhere in this chapter. Minimum requirements for three or more dwelling units:
(1) Average number of units per acre: 20-40;
(2) Lot width: 200 feet;
(3) Yard, building setback:
(a) Front: 50 feet, plus one foot per foot of building height over 50 feet;
(b) Side: 40 feet, plus one-half foot per foot of building height over 50 feet; and
(c) Rear: 40 feet, plus one-half foot per foot of building height over 50 feet.
(4) Distance between principal structures: 50 feet.
(B) Building height: no maximum height for buildings with three or more units.
(C) Storage space requirement: a minimum of 96 cubic feet of miscellaneous storage space shall be provided for each dwelling within the principal structure containing the unit. The space shall be in addition to normal storage space provided in wardrobes, cabinets and closets or linen closets.
(D) (1) Exterior walls of all principal structures must be covered only with siding (e.g., wood, vinyl, aluminum or metal horizontal lap), stucco, brick, glass or other comparable material as approved by the Zoning Administrator.
(2) Prohibited materials include, but are not limited to, cloth, fabric, canvas, plastic sheets, tarps, tarpaper, insulation, sheet metal and corrugated metal.
(Ord. 09-19, passed - -; Ord. passed 10-11-1963; Ord. 16-12, passed 11-14-2016; Ord. 20-019, passed 10- 12-2020)