129.06(A) Every
, except interior rooms, shall have at least one window with a minimum total area of not less than 10% of the floor area of the room or a skylight with a minimum total area of not less than 15% of the floor area of the room.
129.06(A)(1) Windows and skylights shall face directly to the outdoors.
129.06(A)(2) A window shall be deemed not to face directly to the outdoors, and shall not be included in the required minimum total window area, if exterior walls of adjacent
or other light-obstructing
are located less than three feet from the window and extend to a level above the ceiling of the room in which the window occurs.
129.06(B) Every
shall contain:
129.06(B)(1) At least two separate, properly installed and operational floor or wall-type electric outlets; or
129.06(B)(2) One properly installed and operational floor or wall-type electric outlet and one properly installed and operational ceiling-type electric light fixture.
129.06(C) Every bathroom, shower room or water closet compartment shall contain at least one properly installed and operational ceiling or wall-type electric light fixture.
129.06(D) Every hall, stairway and other space or area located within or on the exterior of a
or
shall have operational electric lighting facilities:
129.06(D)(1) Capable of providing not less than one
of light throughout the hall, stairway, other space or area; and
129.06(D)(2) The availability of light from those facilities shall be controlled by the occupants at all times.
(Ord. 2010-22, passed 10-4-2010)