§ 53.22 CONNECTION TO PUBLIC SEWER.
   The connection of the building sewer into the public sewer shall be made at the Y branch, if the branch is available at a suitable location. If the public sewer is 12 inches in diameter or less, and no properly located Y branch is available, the town shall, at the expense of the owner, install a Y branch in the public sewer at the location specified by the Manager. Where the public sewer is greater than 12 inches in diameter, and no properly located Y branch is available, the town shall, at the expense of the owner, cut a neat hole into the public sewer, with entry in the downstream direction at an angle of about 45 degrees, and install a 45-degree ell with the spigot end cut so as not to extend past the inner surface of the public sewer. The invert of the building sewer at the point of connection shall be at the same or at a higher elevation than the invert of the public sewer. A smooth, neat joint shall be made, and the connection made secure and watertight by encasement in concrete. Special fittings may be used for the connection only when approved by the Manager.
(Ord. passed 1-7-1965)