§ 157.801 ROADWAYS AND CURBS.
   Access to the station or other structure or parking lot shall be controlled as follows.
   (A)   Access shall be by not more than two roadways for each 100 feet, or fraction thereof, of frontage on any street.
   (B)   No two of said roadways shall be closer to each other than 12 feet; and no roadway shall be closer to a side property line than three feet.
   (C)   Each roadway shall be not more than 36 feet in width for roadside stands, public parking lots, and all other businesses requiring motor vehicle access, except service stations in Commercial Zones and uses in Manufacturing Zones may have a maximum width of 50 feet.
   (D)   No roadway shall be closer than 20 feet to the point of intersection of two property lines at any street corner.
   (E)   In all cases where there is an existing curb and gutter, or sidewalk, on the street, the applicant for a permit shall provide a safety island along the entire frontage of the property, except for permitted roadways. Concrete curbs shall be constructed and height, location, and structural specifications shall be approved by the City Engineer.
   (F)   Where there is no existing curb and gutter, or sidewalk, the applicant shall install such safety island and curb, or, in place thereof, construct along the entire length of the property line, except in front of the permitted roadways, a curb, fence, or pipe rail not exceeding two feet or less than eight inches in height.
(Prior Code, § 58.04) (Ord. 2-92, passed - -1992) Penalty, see § 157.999