§ 53.05 DISTRIBUTION BOXES.
   (A)   A distribution box or series of distribution boxes shall be installed between the septic tank and the subsurface absorption system and each absorption line shall connect directly thereto. It shall be installed in such a manner that it will remain level and provide equal distribution of flow to the individual lines of the subsurface absorption field.
   (B)   The pipe connecting septic tanks installed in series, the septic tank to the distribution box and the pipe connecting the distribution box to the absorption system must be water-tight and be constructed of cast iron, vitrified clay tile, concrete sewer tile, asbestos cement, copper (hard drawn, type K and L) or plastic sewer pipe or equivalent.
   (C)   Distribution boxes shall be constructed of water-tight concrete, metal or other impervious material.
   (D)   Distribution boxes shall be provided with an opening, such as removable lid, which will serve as a ready access for inspection, cleaning and general maintenance.
(1982 Code, § 91.05) (Ord. passed 1-13-1967; Ord. passed 1-22-1979; Ord. passed 4-29-1985; Ord. passed 11-17-1986) Penalty, see § 53.99