1168.04 PRELIMINARY PLAT FORM AND CONTENTS.
   Upon acceptance of an “Attachment A”, the Owner/Developer shall forward a preliminary plat of the proposed subdivision to the Director. Six (6) copies of the preliminary plat shall be provided twenty (24) x thirty-six (36) inches in size at a scale of 100-feet to 1-inch or larger; and shall contain the following information:
   (a)    Proposed name of the subdivision
   (b)    Name, address, and telephone number of the property owner(s), the Owner/Developer, professional engineer, professional surveyor, and legal counsel (if applicable) associated with the project.
   (c)    North directional arrow and scale bar.
   (d)    Boundaries of proposed development phases.
   (e)    Location of property by section, range, township or Virginia Military District survey and date of most recent survey referenced by deed book and page number, and parcel identification number..
   (f)    Vicinity Map of a scale not less than 2,000-feet to 1-inch indicating the general location of the proposed development within the Village of Waverly.
   (g)    Name of adjacent subdivisions, owners and parcel identification numbers of adjoining parcels, and location of common boundary lines, extended 200 feet beyond the boundary of the proposed subdivision.
   (h)    Portions of the site identified by the Federal Emergency Management Agency (FEMA) as within the Official Flood Hazard Area for the 100-Year Flood, 500-Year Flood as specified on the Official Flood Hazard studies or Flood Insurance Rate Maps (FIRM) for the Village of Waverly and Pike County, Ohio as applicable.
   (i)    Portions of the site subject to federal wetland requirements.
   (j)    Total acreage of the parcel(s) to be subdivided and total acreage of proposed subdivision;
   (k)    Current Zoning of land to be subdivided;
   (l)    List of Private Deed Restrictions including those greater than or in compliance with those required by the Village Zoning Ordinance;
   (m)    Lot boundaries, dimensions of each lot in feet, and approximate acreage of each lot;
   (n)    Number assigned to each lot of the proposed subdivision;
   (o)    Existing physical features or structures.
   (p)    Existing sewers, water mains, transmission lines, culverts and other underground structures within the tract, adjacent to the tract or that will be used in developing the tract, indicating pipe sizes, grades and locations;
   (q)    Line illustration and width in feet of proposed new street(s), curb/gutter, and sidewalks.
   (r)    Line illustration of proposed new sanitary sewer line(s) and water distribution line(s).
   (s)    Other utility system layouts and requirements.
   (t)    Proposed methods for addressing storm runoff and storage.
   (u)    Illustration of any open space, beautification or special lighting.
   (v)    Topographic contours, with elevations referenced to the National Geodetic Survey datum, with intervals no greater than 2-feet at 7% slope, no greater than 4-feet for slopes over 7% and less than or equal to 15%, and no greater than 10-feet for slopes greater than 15%.
   (w)    For commercial and/or industrial development, the location, dimensions and grades of proposed parking and loading areas, alleys, streets and points of vehicular ingress and egress to the site.
   (x)    A statement placed in large type at the center, top of the plat containing the following words: “Preliminary Plat Only, NOT APPROVED for Public Record”
      (Ord. 65-2015. Passed 11-2-15.)