§ 150.49  ACCESSORY STRUCTURES.
   (A)    When accessory structures (sheds, detached garages, etc.) are to be placed within a special flood hazard area, the following criteria shall be met:
      (1)   Accessory structures shall not be used for human habitation (including work, sleeping, living, cooking or restroom areas);
      (2)   Accessory structures shall be designed to have low flood damage potential;
      (3)   Accessory structures shall be constructed and placed on the building site so as to offer the minimum resistance to the flow of floodwaters;
      (4)   Accessory structures shall be firmly anchored in accordance with § 150.40;
      (5)   All service facilities such as electrical and heating equipment shall be installed in accordance with § 150.40; and
      (6)   Openings to relieve hydrostatic pressure during a flood shall be provided below regulatory flood protection elevation in conformance with § 150.45(A).
   (B)   An accessory structure with a footprint less than 150 square feet does not require an elevation or floodproofing certificate.  Elevation or floodproofing certifications are required for all other accessory structures in accordance with § 150.28.
(Ord. passed 4-2-2007; Ord. passed 6-7-2021)