§ 17-1504 PARK REQUIREMENTS.
   (a)   A tract to be used for a manufactured housing park shall be large enough to accommodate 25 or more manufactured units.
   (b)   Each manufactured housing park space shall be not less than 35 feet wide.
   (c)   Manufactured housing parks shall have a maximum density of eight manufactured units per gross acre, and each space shall have not less than 3,000 square feet.
   (d)   The manufactured housing park shall be located on a well-drained site properly graded to insure adequate drainage. Development of the park shall be subject to the stormwater management requirements of Article 26 of this Title.
   (e)   Manufactured housing parks shall provide screening when they abut residential property.
   (f)   Each manufactured housing park having more than ten lots for rent shall reserve an area for child recreation according to the following schedule:
 
Number of Manufactured Housing Units
Minimum Area of Playground
0-10
None required
10-20
1,500 square feet
21-25
2,500 square feet
25 and over
100 square feet per lot
 
   (g)   The recreation area shall be located so as to be free from hazards and provided with play equipment.
   (h)   All new manufactured housing parks shall provide a storm shelter of adequate size to accommodate all occupants. All existing manufactured housing parks (at the date of the adoption of this Title) are encouraged to provide storm shelters.
   (i)   The manufactured housing storm shelter may be approved, after the submission of plans by the applicant, by the Zoning Administrator. The shelter shall be constructed below ground level as a concrete structure or other material approved by the city, and provided with heavy metal doors. It shall be located so as to be accessible to the park residents in a central place with access to the shelter clearly marked.
   (j)   Manufactured housing units shall be located so that there is at least a 20 foot clearance between manufactured houses; provided, however, with respect to manufactured houses parked end-to-end, the clearance shall not be less than ten feet. No manufactured housing unit shall be located less than ten feet from the front driveway.
   (k)   No manufactured housing unit shall be located less than 25 feet from any property line of the manufactured housing park or from any community building within the park, including any washroom, toilet, laundry facilities, or office.
   (l)   All manufactured housing spaces shall abut on an internal driveway that is not less than 24 feet in width; provided, however, that no on-street parking is permitted. If parallel parking is permitted on one side of the street, the width shall be increased to 28 feet, and if parallel parking is permitted on both sides of the street, the width shall be increased to 36 feet. Such driveways shall have unobstructed access to a public street or highway and shall have, as a minimum, a gravel surface or be paved and well maintained and lighted.
   (m)   Manufactured housing parks containing more than 20 units shall provide each lot with a concrete pad for parking two vehicles separate from the road. The minimum pad size shall be 14 feet wide and 16 feet in length. In parks containing less than 20 units, the parking space may be constructed of crushed rock finished to a depth of eight inches.
   (n)   All roadways and walks within the manufactured housing park shall be hard surfaced and provided with night lighting using lamps spaced at intervals of not more than 100 feet.
   (o)   All electrical distribution systems and telephone service systems to each manufactured housing space, except outlets and risers, shall be underground. Each manufactured housing space shall be provided with a 110-volt and 220-volt service with a minimum 100-ampere individual service outlet.
   (p)   Whenever master television antenna systems including cable systems, are to be installed, the complete plans and specifications for the system must be submitted for approval. Distribution to individual manufactured housing spaces shall be underground and shall terminate adjacent to the electrical outlet.
   (q)   Laundry facilities for the exclusive use of the manufactured housing occupants may be provided in a service building.
   (r)   An adequate supply of pure water for drinking and domestic purposes shall be supplied by pipes to all buildings and manufactured housing spaces within the park. Each manufactured housing space shall be provided with a cold water tap at least four inches above the ground. An adequate supply of hot water shall be provided at all times in the service buildings for all washing and laundry facilities.
   (s)   All manufactured housing units within the "M-P" District shall be connected to an approved public water supply and an approved sanitary sewer system with at least a four-inch sewer connection to each manufactured housing unit. The sewer connection shall be provided with suitable fittings so that a water-tight connection can be made between the manufactured housing drain and the sewer connection. Such individual unit connections shall be so constructed that they can be closed when not linked to a manufactured housing unit and shall be trapped in such a manner as to maintain them in an odor-free condition.
   (t)   Each manufactured housing unit shall be secured by anchoring the superstructure against uplift, sliding, rotation, and overturning.
   (u)   Outdoor laundry drying space of adequate area and suitable location shall be provided and indicated upon required plan.
   (v)   The owner or operator shall include with the required plan the method of refuse collection and the location of refuse containers. Refuse and garbage handling methods shall meet the following minimum requirements:
      (1)   Storage collection and disposal of refuse in a park shall be so conducted as to create no health hazards, rodent harborage, insect breeding areas, accidents, fire hazards or air pollution.
      (2)   All refuse shall be stored in fly-tight, water-tight, rodent-proof containers. Containers shall be provided in sufficient number and capacity to properly store all refuse.
      (3)   Refuse racks shall be provided for all refuse containers. Such racks shall be designed as to prevent the containers from being tipped, to minimize spillage and container deterioration and to facilitate cleaning around them.
      (4)   Refuse and garbage shall be removed from the park at least once each week. All refuse shall be collected and transported in covered vehicles or covered containers.
      (5)   The park owner shall insure that container at all stands are emptied regularly and maintained in a useable sanitary condition.
   (w)   If only independent manufactured housing spaces are to be provided, no service building will be required; however, when such service building is required, it shall comply with the following regulations:
      (1)   Be located 20 feet or more from any manufactured housing unit.
      (2)   Be adequately lighted.
      (3)   Have the interior finished with moisture-resistant material to permit frequent washing and cleaning.
      (4)   Provide at least one lavatory, water closet, and shower for each sex; one laundry tray, one floor drain, and hot and cold water.
      (5)   Have adequate heating facilities for the building and equipment which will furnish an ample supply of heated water during time of peak demands.
      (6)   Have all rooms well ventilated with all openings effectively screened.
   (x)   When liquefied petroleum gas is used in a mobile home park, containers for such gas shall not hold more than 25 gallons water capacity, shall be the liquefied petroleum gas containers approved by the United States Commerce Commission for its intended purposes, and shall be attached to the mobile home in a manner approved by the Liquefied Petroleum Gas Association.
   (y)   A solid or semi-solid fence or wall, minimum six feet, maximum eight feet high, shall be provided between the manufactured home park district and any adjoining property or property immediately across the alley which is zoned for residential purposes other than for manufactured homes. Said fence shall be so located as defined by this regulation. In lieu of said fence or wall, a landscape buffer may be provided not less than 15 feet in width, and said landscape buffer shall be planted with coniferous and deciduous plant material so as to provide proper screening for the park. When the landscape buffer is used in lieu of the fence or wall, the landscape buffer shall not be included as any part of a required rear yard for a mobile home space. The fence, wall, or landscape buffer shall be properly policed and maintained by the owner.
   (z)   The owner or operator shall include with the required plan a budget for financing the proposed improvements.