In all areas of special flood hazards, the following provisions are required.
(A) Residential construction. New construction and substantial improvement of any residential structure shall have the lowest floor (including basement) elevated at least two feet above the base flood elevation. A registered professional engineer, architect, or land surveyor shall submit a certification to the Floodplain Administrator that the standard of this division (A) is satisfied (elevation certificate).
(B) Nonresidential construction. New construction and substantial improvements of any commercial, industrial, or other nonresidential structure shall have the lowest floor (including basement) elevated at least two feet above the base flood elevation. A registered professional engineer, architect, or land surveyor shall submit a certification to the Floodplain Administrator that the standard of this division (B) is satisfied.
(C) Enclosures.
(1) New construction and substantial improvements, with fully enclosed areas below the lowest floor that are usable solely for parking of vehicles, building access, or storage in an area other than a basement and which are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of flood waters.
(2) Designs for meeting this requirement must either be certified by a registered professional engineer or architect or meet or exceed the following minimum criteria:
(a) A minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided;
(b) The bottom of all openings shall be no higher than one foot above grade; and
(c) Openings may be equipped with screens, louvers, valves, or other coverings or devices, provided that they permit the automatic entry and exit of flood waters.
(D) Manufactured homes.
(1) All manufactured homes to be placed anywhere within the community in flood Zone A on the city FIRM shall be installed using methods and practices that minimize flood damage and have the bottom of the I-beam elevated at least two feet above the base flood elevation. For the purposes of this requirement, manufactured homes must be elevated and anchored on a permanent foundation to resist flotation, collapse, or lateral movement.
(2) This requirement is in addition to applicable state and local anchoring requirements for resisting wind forces. The manufactured home shall be installed by a licensed installer according to state law, and compliance herewith shall be certified in writing to the Floodplain Administrator by said installer prior to habitation of the manufactured home.
(E) Recreational vehicles. Recreational vehicles placed on sites within Zone A on the city’s FIRM either:
(1) Be on the site for fewer than 180 consecutive days;
(2) Be fully licensed and ready for highway use; or
(3) Meet the permit requirements of § 152.04(C), and the elevation and anchoring requirements for manufactured homes in division (D) above. A recreational vehicle is ready for highway use if it is on its wheels or its jacking system, is attached to the site only by quick disconnect type utilities and security devices, and has no permanently attached additions.
(F) Accessory structure. Accessory structures to be placed on sites within Zone A on the city’s FIRM shall comply with the following.
(1) The structure shall be unfinished on the interior.
(2) The structure shall be used only for parking and limited storage.
(3) The structure shall not be used for human habitation. Prohibited activities or uses include, but are not limited to, working, sleeping, living, cooking, or restroom use.
(4) Service facilities such as electrical and heating equipment must be elevated two feet above the BFE and meet NEC and the Plumbing and Mechanical Codes.
(5) The structure shall be constructed and placed on the building site so as to offer the minimum resistance to the flow of flood waters.
(6) The structure shall be designed to have low flood damage potential and constructed with flood resistance materials.
(7) The structure shall be firmly anchored to prevent flotation, collapse, and lateral movement.
(8) Floodway requirements must be met in the construction of the structure.
(9) Openings to relieve hydrostatic pressure during a flood shall be provided below the BFE.
(10) The structure shall be located so as not to cause damage to adjacent and nearby structures.
(Prior Code, § 152.21) (Ord. 12-1692, passed 6-5-2012) Penalty, see § 152.99