§ 162.062 RESIDENTIAL CONSERVANCY.
   (A)   Purpose. To allow for limited development in areas of the city where topography or natural resources require careful alterations to the land and placement of structures and infrastructure.
   (B)   Uses. See the Use Chart located in § 162.060 of this chapter for all permitted, conditional and interim uses.
   (C)   Standards, district performance standards.
      (1)   Lot standards.
 
Bluff setback (top/toe of bluff)
30 feet
Maximum height
35 feet
Maximum residential density
2 dwelling units per acre
Minimum lot frontage
25 feet
Minimum lot size (private sewer)
20,000 square feet
Minimum lot size (city sewer)
9,600 square feet
Minimum lot width
60 feet
 
      (2)   Principal building setbacks.
 
Corner side street
10 feet
Front
25 feet
Rear
25 feet
Side
5 feet
 
      (3)   Accessory building setbacks.
 
Corner side street
10 feet
Front
Behind principle structure
Rear
3 feet
Side
3 feet
 
      (4)   Septic systems.
         (a)   Sites on septic systems must be able to provide two individual septic locations, a primary and a backup which are indicated on the site plan.
         (b)   All septic systems must meet the standards identified by the state’s Pollution Control Agency in Minn. Rules Ch. 7080.
(Prior Code, § 305.06) (Ord. passed 12-18-2007; Ord. passed 7-2-2018)