(a) In an A-1 District utility buildings shall not be larger than 7.5 percent of the rear yard, and the height shall not exceed 135 percent of the side of least dimensions; in all other zoning districts utility buildings shall not exceed 320 square feet and shall not exceed twelve feet in maximum height or the height of the primary structure, or whichever is the lesser amount.
(Ord. 01-4. Passed 2-19-01.)
(b) Utility buildings are to be located in the rear yard in such manner that there is no drainage onto adjacent property.
(Ord. 73-70. Passed 7-23-73.)
(c) The rear yard minimum setback for utility buildings shall be five feet. The side yard setback shall be the same as is required for the main building, except in an RS Special Residence District, wherein a six foot side setback is required.
(Ord. 73-92. Passed 11-19-73.)
(d) No utility buildings in combination with other detached garages or accessory buildings shall exceed thirty percent of all rear yard coverage.
(Ord. 01-4. Passed 2-19-01.)
(e) The use of a metal shipping container or temporary storage container, as defined in Section 1272.17, as a permanent utility/accessory building is strictly prohibited.
(Ord. 2018-60. Passed 10-22-18.)