Photographs on record with the Department of Community Development and the following legal descriptions are hereby approved and adopted as official view corridors protecting views within the town. The photographs taken represent the boundaries defined by the legal descriptions. The camera used to take the photographs was held five and four-tenths feet above the instrument, which is approximate eye level for most adults. A 35 millimeter camera was used for each photograph; however, once developed, some photographs were cropped or enlarged to improve the graphic representation of each view corridor.
(A) View Point #1. A view from the south side of the Vail Transportation Center from the main pedestrian stairway looking toward the Clock Tower, 232 Bridge Street, the Rucksack Tower, 280 Bridge Street, and beyond to the ski slopes.
(1) Purpose. To protect the views of Vail Mountain, views of Vail Village and to maintain the prominence and views of the Clock Tower and Rucksack Tower as seen from the central staircase of the Transportation Center.
(2) Instrument; View Point #1. A two-inch diameter brass disc, marked V.P. 1 on stair landing between levels 2 and 3 of Vail Village parking structure.
(3) Backsight. CW 1/16 corner of Section 8.
(4) Height of survey transit above View Point #1. Five and four-tenths feet.
(5) Table.
Horizontal Angle | Zenith Angle | Foresight Point On Photo As Of Feb. 7, 1992 |
Horizontal Angle | Zenith Angle | Foresight Point On Photo As Of Feb. 7, 1992 |
348°51’10” | 77°21’30” | A - intersection of the horizon with a vertical line defined by the southwest corner of the sixth floor deck enclosure on the Mountain Haus, 292 E. Meadow Drive |
348°30’10” | 87°11’30” | B1 - uppermost railing of the southwest corner of the balcony on the fourth floor of the Mountain Haus, 292 E. Meadow Drive |
355°23’00” | 87°37’40” | B2 - east end of the Red Lion roof ridge, 304 Bridge Street |
357°39’04” | 87°40’43” | B3 - intersection of the Red Lion roof ridge with the southeast corner of the Rucksack Tower, 280 Bridge Street |
357°57’59” | 88°27’22” | B4 - northeast corner of the base of the Rucksack Tower, 280 Bridge Street |
004°05’19” | 89°16’02” | C1 - intersection of the Gallery Building, 225 Gore Creek Drive, with the northeast corner of the Clock Tower, immediately below the balcony |
004°39’58” | 89°16’33” | C2 - western end of fascia board on Gallery Building |
004°47’18” | 89°41’44” | C3 - intersection of the sloping roof of the Gallery Building with the ridge line of the Clock Tower Building, which extends west |
006°59’11” | 89°42’12” | D - intersection of the Clock Tower Building roof and the northwest corner of the Clock Tower |
012°25’56” | 87°39’01” | E - peak of the Plaza Lodge vent chase, 232 Bridge Street |
027°08’54” | 87°28’43” | F - intersection of the north side of roof, Gasthof Gramshammer Building, 231 East Gore Creek Drive, with the east side of 2 large trees |
031°53’27” | 76°26’35” | G - intersection of the horizon line on Vail Mountain with the vertical line defined by the top of the western, very large pine tree west of Point F |
(B) View Point #2. A view from upper Bridge Street looking toward the ski slopes between 228 Bridge Street, the Golden Peak Building, and 311 Bridge Street, the Hill Building.
(1) Purpose. To protect views of the ski runs and ski base area as seen from upper Bridge Street.
(2) Instrument; View Point #2. A #6 rebar with a two and one-half inch diameter aluminum cap marked V.P. 2 (PLS 16827) set in an aluminum monument box in Bridge Street in front of the Red Lion Building, 304 Bridge Street.
(3) Backsight; View Point #4. A #6 rebar with a two and one-half inch diameter aluminum cap marked V.P. 4 (PLS 16827) set in an aluminum monument box, in the brick pavers, approximately eight feet from the entrance to Frivolous Sal’s, located near the northeast corner of One Vail Place Building, 244 Wall Street.
(4) Height of survey transit above View Point #2. Five and four-tenths feet.
(5) Table.
Horizontal Angle | Zenith Angle | Foresight Point On Photo As Of Nov. 15, 1991 |
289°25’48” | 74°28’18” | A - northwest corner of third floor balcony roof of Golden Peak Building |
290°58’11” | 89°58’00” | B - PK nail in top of the 24 inch tall retaining wall on west side of Golden Peak House, 1 foot east from west edge of planter wall, and 10 feet west from the west face of the building |
300°32’46” | 92°05’34” | C1 - top of south end of ski lockers, which are on railing |
301°35’24” | 83°31’08” | C2 - southeast corner of top deck rail on Hill Building |
303°32’24” | 73°38’55” | D - southeast corner of brick chimney on Hill Building |
(C) View Point #4. A view from the northeast corner of 244 Wall Street, the One Vail Place Building, looking over the roofs of 304 Bridge Street, the Red Lion Building, and 356 Hanson Ranch Road, the Christiania Lodge, toward the Gore Range.
(1) Purpose. To protect views of the Gore Range as seen from the alley between Founders Plaza and Seibert Circle.
(2) Instrument; View Point #4. A #6 rebar with a two and one-half inch diameter aluminum cap marked V.P. 4 (PLS 16827) set in an aluminum monument box, in the brick pavers, approximately eight feet from the entrance to Frivolous Sal’s, located in the northeast corner of the One Vail Place Building, 244 Wall Street.
(3) Backsight; View Point #2. A #6 rebar with a two and one-half inch diameter aluminum cap marked V.P. 2 (PLS 16827) set in an aluminum monument box in Bridge Street in front of the Red Lion Building.
(4) Height of survey transit above View Point #4. Five and four-tenths feet.
(5) Table.
Horizontal Angle | Zenith Angle | Foresight Point on Photo as of Nov. 15, 1991
|
Horizontal Angle | Zenith Angle | Foresight Point on Photo as of Nov. 15, 1991
|
343°56’53” | 62°24’10” | A - south fascia board of third floor roof of Plaza Lodge Building, 281 – 293 Bridge Street |
348°37’05” | 73°05’43” | B - intersection of upper and second floor roof lines of Plaza Lodge Building |
352°55’25” | 73°34’26” | C - south end of peak of second floor gable of Plaza Lodge Building |
352°31’05” | 79°24’44” | D - eastern edge of second floor gable roof of Plaza Lodge Building |
352°13’16” | 79°24’55” | E - intersection of second floor roof fascia and southeast corner of Plaza Lodge Building |
352°13’14” | 84°44’25” | F - intersection of southeast corner of building and top edge of first floor fascia of Plaza Lodge Building |
354°30’20” | 86°13’30” | G - top of southeasterly corner of first floor fascia of Plaza Lodge Building |
354°47’22” | 86°07’58” | H - intersection of south edge of Red Lion chimney and upper Red Lion roof line |
358°21’46” | 85°17’48” | I - peak of upper Red Lion roof line |
359°04’31” | 85°30’36” | J - intersection of upper Red Lion roof line and northerly roof line of the Christiania |
000°16’55” | 84°36’56” | K - peak of northerly roof line of the Christiania |
001°59’47” | 84°36’56” | L - intersection of northerly roof peak and southerly roof line of the Christiania |
003°05’44” | 83°32’42” | M - northwesterly corner of second floor balcony on Hill Building |
006°23’31” | 83°33’52” | N - intersection of top of second floor balcony rail and brick wall on Hill Building |
005°32’14” | 67°54’58” | O - northwest corner of top of fascia on third floor roof of Hill Building |
(D) View Point #5. A view of the Gore Range from Hanson Ranch Road just east of the Mill Creek Bridge and south of 302 Gore Creek Drive, the Mill Creek Court Building.
(1) Purpose. To protect views of the Gore Range as seen from Hanson Ranch Road and East Gore Creek Drive.
(2) Instrument; View Point #5. A #6 rebar with two and one-half inch diameter aluminum cap marked V.P. 5 (PLS 16827) set in an aluminum monument box in Hanson Ranch Road in front of the Mill Creek Court Building.
(3) Backsight. #4 rebar with aluminum cap (LS 2568) in iron “Landmark” monument box marking center line of Hanson Ranch Road - box is just west of Mill Creek in front of the Cyrano’s Building at 298 Hanson Ranch Road.
(4) Height of survey transit above View Point #5. Five and four-tenths feet.
(5) Table.
Horizontal Angle | Zenith Angle | Foresight Point On Photo As Of Nov. 15, 1991 |
Horizontal Angle | Zenith Angle | Foresight Point On Photo As Of Nov. 15, 1991 |
199°03’06” | 81°23’49” | A - intersection of southerly utility pole with ridge line |
204°06’43” | 85°10’40” | B1 - intersection of northerly extension of Garden of the Gods Building, roof line with hillside ridge line |
206°00’02” | 85°10’40” | B2 - northern end of roof line of the Garden of the Gods Building, 365 Vail Valley Drive |
208°12’53” | 85°10’40” | C1 - intersection of southerly extension of the Garden of the Gods building roof line and the Villa Valhalla roof line, 360 Hanson Ranch Road |
208°33’36” | 84°55’50” | C2 - northwest corner of the Villa Valhalla at roof fascia |
210°41’41” | 84°01’47” | D - intersection of top of the Villa Valhalla roof fascia and the upward extension of the north edge of the trim on the window column |
210°41’41” | 82°01’51” | E - the upward extension of the north edge of the trim on the window column on the Villa Valhalla to a point above the horizon |
(E) View Point #6. A view looking east to the Gore Range from Gore Creek Drive between retail shops at 174 Gore Creek Drive, the Lodge at Vail, and 193 Gore Creek Drive, the Gore Creek Plaza Building projecting east to the Gore Range.
(1) Purpose. To protect views of the Gore Range as seen from the Gore Creek Drive Area.
(2) Instrument; View Point #6. A #6 rebar with two and one-half inch diameter aluminum cap marked V.P. 6 (PLS 16827) set in an aluminum monument box in Gore Creek Drive in front of the Gore Creek Plaza Building.
(3) Backsight. A #6 rebar with a two and one-half inch diameter aluminum cap marked V.P. 6 B.S. (PLS 16827) set in an aluminum monument box in Gore Creek Drive near the southwest corner of Pepi’s deck.
(4) Height of survey transit above View Point #6. Five and four-tenths feet.
(5) Table.
Horizontal Angle | Zenith Angle | Foresight Point On Photo As Of Nov. 15, 1991 |
Horizontal Angle | Zenith Angle | Foresight Point On Photo As Of Nov. 15, 1991 |
356°08’35” | 81°02’17” | A - point on horizon left of the chimney on Gasthof Gramshammer roof, 231 East Gore Creek Drive |
356°55’02” | 83°02’06” | B - intersection of southeast edge of chimney and Gasthof Gramshammer’s roof line |
000°31’36” | 82°54’27” | C - southern end of gable on Gasthof Gramshammer’s roof |
001°48’10” | 85°17’34” | D1 - intersection of northerly extension of Gorsuch Building’s roof line and Gasthof Gramshammer’s roof, 231 East Gore Creek Drive |
003°14’42” | 85°17’40” | D2 - north end of Gorsuch Building’s roof |
007°56’03” | 85°11’32” | D3 - south end of Gorsuch Building’s roof |
013°30’31” | 85°11’32” | E - intersection of southerly extension of Gorsuch Building’s roof line and brick pillar on Lazier Arcade Building/Wall Street Building, 225 Wall Street |
013°38’14” | 78°48’35” | F - intersection of face of stucco and eaves line on Lazier Arcade Building/Wall Street Building |
012°55’17” | 78°14’51” | G - top of fascia on northeast corner of roof on Lazier Arcade Building/Wall Street Building |
014°44’21” | 73°13’39” | H - top of roof on Lazier Arcade Building/Wall Street Building |
(F) View Point #7. A view from the west end of the Lionshead parking structure, standing at street level at the front of the entrance to the Subway restaurant (395 E. Lionshead Circle) and looking southwest toward the gondola lift line.
(1) Purpose. To protect the views of Vail Mountain from the Lionshead area.
(2) Survey control. Based on published material from Town of Vail GPS control map. Points Spraddle and 1766 were used for this survey. Bearings reported below are tied to this control.
(3) Instrument; View Point #7. A two inch diameter brass monument, flush in brick payers, stamped View 7.
(4) Backsight. A two inch diameter aluminum Johnson, Kunkel & Associates, Inc., monument which bears S11°47’42”W 327.94 feet distant. Located at the north edge of a concrete ring for a water manhole approximately 15 feet north of the north edge of the bike path.
(5) Height of survey instrument above View Point #7. Five and twenty-six one-hundredths feet.
(6) Table.
Bearing | Zenith Angle | Foresight Point On Photo As Of June 12, 2001 |
Bearing | Zenith Angle | Foresight Point On Photo As Of June 12, 2001 |
S05°14’25”W | 79°09’13” | A - intersection of the horizon with a vertical line defined by the southwest corner roofline on the Treetops Condominium building, 452 E. Lionshead Circle |
S05°22’18”W | 80°11’31” | B - intersection of the roof overhang at the west end of the Treetops Condominium building and the southwest corner of said building, 452 E. Lionshead Circle |
S05°38’24”W | 80°17’55” | B1 - westerly upper corner of the roof overhang at the west end of the Treetops Condominium building, 452 E. Lionshead Circle |
S05°48’38”W | 81°42’54” | B2 - westerly lower corner of the roof overhang at the west end of the Treetops Condominium building, 452 E. Lionshead Circle |
S05°22’28”W | 81°43’15” | B3 - intersection of the roof overhang at the west end of the Treetops Condominium building and the southwest corner of said building, 452 E. Lionshead Circle |
S05°22’28”W | 90°01’11” | B4 - a point on the westerly edge of the Treetops Condominium building, 452 E. Lionshead Circle and running horizontal with and perpendicular to the southeast corner roofline of the bus stop building at Lionshead Circle |
S24°16’45”W | 90°01’11” | C - southeast corner roofline of the bus stop building at Lionshead Circle. Said point being the lower limit of View Point #7, intersecting with the vertical line described below for point D and running horizontal with and perpendicular to the westerly edge of the Treetops Condominium building, 452 E. Lionshead Circle |
S23°11’03”W | 85°40’57” | D - intersection of the horizon with a vertical line defined by the southeast corner roofline on the Vail Lionshead Centre Condominiums, 520, Lionshead Circle |
S23°11’03”W | 79°09’13” | E - point of intersection of the southwest roofline of said Treetops Condominiums building defined by point A and the southeast corner of said Vail Lionshead Condominium building as defined by point D |
(G) View Point #8. A view from the pedestrian plaza at the east end of the Lifthouse Lodge (555 E. Lionshead Circle) looking south directly up the gondola lift line.
(1) Purpose. To protect the views of Vail Mountain from the core of the Lionshead area.
(2) Survey control. Based on published material from Town of Vail GPS control map. Points Spraddle and 1766 were used for this survey. Bearings reported below are tied to this control.
(3) Instrument; View Point #8. A two and one-half inch diameter aluminum monument, flush in brick pavers, stamped View 8.
(4) Backsight. A two and one-half inch diameter aluminum monument, which bears S84°22’18”W a distance of 164.53 feet. Located flush on top of the stone wall running east to west in front of the Montauk Deck east of the main entrance, stamped CP Montauk.
(5) Height of survey instrument above View Point #8. Five and three-tenths feet (to match previous height before streetscape).
(6) (1) Table.
Horizontal Angle | Zenith Angle | Foresight Point On Photo As Of July 8, 2008 |
Horizontal Angle | Zenith Angle | Foresight Point On Photo As Of July 8, 2008 |
267°00’33” | 79°08'’15” | A - intersection of the horizon with a vertical line defined by the southerly roof line on the Vail Lionshead Centre Condominiums, 520 E. Lionshead Circle |
266°52’31” | 85°10’55” | B - intersection of a lower roof at the westerly end and the westerly building wall of the Vail Lionshead Centre Condominiums |
268°09’29” | 85°55’59” | C - westerly end of the lower roof on the westerly end of the Vail Lionshead Centre Condominiums |
267°50’34” | 87°46’40” | D - intersection of the red awning and the westerly wall of the Vail Lionshead Centre Condominiums |
269°10’34” | 87°51’15” | E - top westerly corner of red awning |
269°10’34” | 88°28’56” | F - point of intersection of the red awning and the main level roofline on the westerly end of the Vail Lionshead Centre Condominiums |
271°54’54” | 88°28’56” | G - point of intersection of a line projected from View Point F across the Eagle Bahn Gondola ski yard to the support post of the sloped roof of the terrace on the 1st level along the east side of the Arrabelle at Vail Square |
281°17’48” | 87°51’18” | H - underside intersection of sloped roof and the support post of the terrace on the 1st level on the east side of Arrabelle at Vail Square |
280°52’19” | 87°46’16” | I - underside of sloped roof of the terrace on the first level on the east side of Arrabelle at Vail Square |
280°42’31” | 87°24’36” | J - top edge of overhang/beginning of sloped roof of the terrace at the 1st level on the east side of the Arrabelle at Vail Square |
281°30’24” | 87°06’00” | K - intersection of sloped roof of the terrace at the 1st level and the east wall of the Arrabelle at Vail Square |
281°31’32” | 79°37’37” | L - intersection of the east wall of the Arrabelle at Vail Square and the bottom outer edge of the concrete deck on the 6th level of the Arrabelle at Vail Square |
281°09’32” | 79°02’30” | M - top outer edge of concrete deck on the 6th level of the Arrabelle at Vail Square |
O - line projected from View Point M straight up to the horizon line of Vail Mountain | ||
(2) Permitted. The following are permitted within View Corridor #8: drain pipes; roof snow fences; streetlights; decorative outdoor lights/lighting; ski lifts/tows and appurtenances; ski area installations and appurtenances, e.g., signs, fencing; other items not comprising the structure of the building; all structures permitted under this code contained within the following described parcels:
(a) Parcels A and B, Lot 1, Block 2, Vail Village Sixth Filing;
(b) Units A and B, Lot 5, Block 4, Vail Village Third Filing;
(c) Lot 4, Block 4, Vail Village Third Filing (a.k.a. Beaver Dam Condominiums);
(d) Parcels A and B, Lot 1, Block 1, Vail Village Sixth Filing;
(e) Units 1 and 2, House in Forest Condominiums;
(f) Parcels A and B, Lot 3, Block 1, Vail Village Sixth Filing;
(g) Lots 1 and 3, Forest Place Subdivision; and
(h) Lot 6, Block 1, Vail Village Third Filing.
(H) View Point #9. A view from the top west stair above the ice rink of the Arrabelle at Vail Square looking south across the pedestrian mall of the Arrabelle at Vail Square towards the Eagle Bahn Gondola.
(1) Purpose. To protect the views of Vail Mountain from the core of the Lionshead area.
(2) Survey control. Based on published material from Town of Vail GPS control map. Points Spraddle and 1766 were used for this survey. Bearings reported below are tied to this control.
(3) Instrument; View Point #9. A two and one-half inch diameter aluminum monument, set at the center of the top of the west stair above the ice rink of the Arrabelle flush in pavers, stamped View 9.
(4) Backsight. A two and one-half inch diameter aluminum monument, which bears S84°22’18”W a distance of 164.53 feet. Located flush on top of the stone wall running east to west in front of the Montauk Deck east of the main entrance, stamped CP Montauk.
(5) Height of survey instrument above View Point #9. Five and two-tenths feet.
(6) (1) Table.
Horizontal Angle | Zenith Angle | Foresight Point On Photo As Of June 1, 2008 |
Horizontal Angle | Zenith Angle | Foresight Point On Photo As Of June 1, 2008 |
67°13’19” | 83°39’37” | A - intersection of underside of the pedestrian bridge and the east wall at the 3rd level |
67°13’16” | 84°01’27” | B - intersection of east wall and sloped roof at the third level |
68°58’53” | 84°34’10” | C - east end of sloped roof/top of deck railing at the third level |
68°58’15” | 86°49’52” | D - underside of outermost edge of terrace on the east side of the third level |
68°19’45” | 86°54’20” | E - intersection of east wall and underside of terrace of the third level |
68°19’36” | 90°52’16” | F - angle point in east wall |
68°51’23” | 94°34’30” | G - intersection of east wall at ground level |
71°35’08” | 93°11’36” | H - intersection of west wall at ground level |
71°40’40” | 91°48’13” | I - angle point of west wall |
72°18’05” | 90°07’47” | J - angle point of west wall |
72°17’49” | 89°39’20” | K - top of the great room terrace wall at the second level |
74°14’07” | 89°32’05” | L - intersection of the great room terrace wall at the second level and the east side of the outdoor fireplace chimney in the pedestrian plaza |
74°36’40” | 87°55’34” | M - angle point of the east side of the outdoor fireplace chimney and the intersection of the underside of sloped roof overhang at the second level |
74°09’55” | 87°56’16” | N - underside of sloped roof overhang at the second level |
73°52’09” | 87°36’45” | O - top side of sloped roof overhang for the second level |
74°36’25” | 86°58’15” | P - intersection of sloped roof for the second level and the fireplace chimney |
74°32’38” | 84°09’29” | Q - top east side of the fireplace chimney |
76°31’13” | 83°59’23” | R - top west side of the fireplace chimney |
76°28’06” | 86°17’44” | S - intersection of the west side of the fireplace chimney and sloped roof for the second level |
78°20’42” | 85°21’48” | T - intersection of sloped roof and dormer overhang at the third level |
78°58’36” | 83°28’40” | U - intersection of dormer overhang at the third level and the underside of the pedestrian bridge |
(2) Permitted. The following are permitted within View Corridor #9: aboveground pedestrian bridge connecting buildings; maypole and attachments; signs attached to the building; umbrellas located on decks, skier bridge and appurtenances; menu boards; movie screens; decorative outdoor lights/lighting; railings defining restaurant decks; flower containers; directional/directory signs; trash containers; bollards; roof snow fences; streetlights; ski lifts/tows and appurtenances; ski area installations and appurtenances, e.g., signs, fencing; other items not comprising the structure of the building; all structures permitted under this code contained within the following described parcels:
(a) Parcels A and B, Lot 1, Block 2, Vail Village Sixth Filing;
(b) Units A and B, Lot 5, Block 4, Vail Village Third Filing;
(c) Lot 4, Block 4, Vail Village Third Filing (a.k.a. Beaver Dam Condominiums); and
(d) Parcels A and B, Lot 1, Block 1, Vail Village Sixth Filing.
(I) View Point #10. A view from the top of the stairs east of the Landmark building looking south directly up the Eagle Bahn Gondola lift line through the Arrabelle at Vail Square to the horizon line of Vail Mountain.
(1) Purpose. To protect the views of Vail Mountain from the core of the Lionshead area.
(2) Survey control. Based on published material from Town of Vail GPS control map. Points Spraddle and 1766 were used for this survey. Bearings reported below are tied to this control.
(3) Instrument; View Point #10. A two and one-half inch diameter aluminum monument, located 25 feet north west of the top step east of the Landmark building in the grass, near the bend in the sidewalk heading toward the North Day Lot, stamped View 10.
(4) Backsight. A two and one-half inch diameter aluminum monument which bears S10°14’26”E a distance of 171.51 feet. Located on the top of the west stair above the ice rink of the Arrabelle at Vail Square flush in pavers, stamped View 9.
(5) Height of survey instrument above View Point #10. Five and two-tenths feet.
(6) (1) Table.
Horizontal Angle | Zenith Angle | Foresight Point On Photo As Of June 1, 2008 |
Horizontal Angle | Zenith Angle | Foresight Point On Photo As Of June 1, 2008 |
350°36’14" | 79°31’45” | A - intersection of roof line of the seventh level and evergreen tree |
353°22’18” | 79°23’31” | B - west edge of roof line of the seventh level |
353°35’53” | 80°22’46” | C - point along the sloping overhang roof line and a line projected from the top of the ball on the finial cap at the seventh level |
354°19’54” | 80°22’46” | D - line intersection projected from View Point C and a line from the west edge of the finial cap at the seventh level |
354°19’54” | 81°11’30” | E - intersection of west edge of the finial cap and the covered outside terrace curved roof line at the seventh level |
355°31’32” | 81°39’33” | F - intersection of the covered outside terrace curved roof line and the air louver on the west side of the seventh level |
355°58’38” | 81°39’33” | G - west outer edge of air louver on covered outside terrace curved roof line along the west wall of the seventh level |
356°06’33” | 85°03’26” | H - intersection of the seventh level west wall and the top of terrace railing at the sixth level |
357°08’18” | 85°15’26” | I - west outer edge of the top terrace railing at the sixth level |
357°10’48” | 85°53’17” | J - west outer edge at the bottom of the decking at the sixth level |
356°05’50” | 86°25’18” | K - intersection of the plaza area east wall and the bottom of the decking at the sixth level |
356°04’55” | 87°47’08” | L - intersection of the plaza area east wall and the sloped roof |
356°25’23” | 88°07’16” | M - west outer edge of sloped roof |
356°04’55” | 88°23’50” | N - intersection of the plaza area east wall and the underside of the sloped roof |
356°05’50” | 89°15’05” | O - intersection of the plaza area east wall and the top of the pedestrian bridge |
02°45’18” | 89°14’43” | P - intersection of the pedestrian bridge and the eastern point of the dormer roof line for the third level |
02°45’18” | 89°07’46” | Q - top eastern point of the dormer roof line of the third level |
03°35’07” | 89°07’14” | R - intersection of the dormer roof line at the third level and the stucco support column for the terrace for the 3rd level |
03°35’07” | 89°02’37” | S - east corner of stucco support column for the third level |
03°43’19” | 89°01’45” | T - intersection of wood support post and the top base of stucco column for the third level |
03°43’19” | 88°15’55” | U - underside of sloped roof overhang for the third level roof overhang |
03°11’51” | 88°01’36” | V - east outer edge of sloped roof overhang for the third level roof overhang |
04°06’01” | 85°17’14” | W - top east edge of roof line for the third level roof overhang |
06°47’20” | 85°22’54” | X - an intersection point of a line projected along the roof line for the third level and a line projecting down from the underside of the fifth level deck |
06°47’20” | 83°33’42” | Y - top east edge of the terrace railing at the fifth level |
07°35’22” | 83°33’18” | Z - intersection of a line projecting along the top edge of the terrace railing at the fifth level to a point on the concrete terrace patio at the sixth level |
08°02’43” | 78°52’04” | A1 - a line projected from the described point in View Point W to the east outer edge of the roof line at the sixth level |
09°32’54” | 78°52x’04” | B1 - an intersection point of a line projected along the sixth level roof line and the copper gutter of the Clock Tower |
09°57’53” | 76°04’24” | C1 - a line projected from the described point in View Point Y to the eastern edge of the sloped roof line of the turret for the sixth level |
(2) Permitted. The following are permitted within view corridor #10: drain pipes; snow cable clips; flower boxes; roof snow fences; decorative outdoor lights/lighting; ski lifts/tows and appurtenances; ski area installations and appurtenances, e.g., signs, fencing; other items not comprising the structure of the building; all structures permitted under this code contained within the following described parcels:
(a) Parcels A and B, Lot 1, Block 2, Vail Village Sixth Filing;
(b) Units A and B, Lot 5, Block 4, Vail Village Third Filing;
(c) Lot 4, Block 4, Vail Village Third Filing (a.k.a. Beaver Dam Condominiums);
(d) Parcels A and B, Lot 1, Block 1, Vail Village Sixth Filing;
(e) Units 1 and 2, House in Forest Condominiums;
(f) Parcels A and B, Lot 3, Block 1, Vail Village Sixth Filing;
(g) Lots 1 and 3, Forest Place Subdivision; and
(h) Lot 6, Block 1, Vail Village Third Filing.
(Ord. 18(1992) § 1; Ord. 16(2002) § 1; Ord. 23(2008) § 1)