A. In addition to the
application requirements normally required under Chapter 73, Building Construction, the Township Building Code Official shall require the following specific information to be included as part of an application for a
in the Floodplain Conservation District:
(1) For
to be elevated:
(a) A plan showing the size of the proposed
and its relation to the
where it is to be constructed.
(b) A determination of elevations of the existing grade, proposed finished grade and
certified by a registered professional engineer.
(c) Plans showing the method of elevating the proposed
, including details of proposed fills, pile
, retaining walls, foundations, erosion protection measures, etc. When required by the Building Code Official, these plans shall be prepared by a registered professional engineer or architect.
(d) Plans showing the methods used to protect utilities (including sewer, water, telephone, electric, gas, etc.) from flooding to an elevation at least one and one-half feet above the
at the
site.
(2) For
to be floodproofed:
(a) Plans showing details of all
measures, prepared by a registered professional engineer and showing the size of the proposed
and its relation to the
where it is to be constructed.
(b) A determination of elevations of existing grades, proposed finished grades,
and
limits; certified by a registered professional engineer.
(c) A certificate prepared by a registered professional engineer who prepared the plans that the
in question, together with attendant utility and sanitary facilities, is designated so that:
(i) Below an elevation two feet above the
the
is watertight with walls substantially impermeable to the passage of water.
(ii) The
will withstand the hydrostatic, hydrodynamic, buoyant, impact and other forces resulting from the
depths, velocities, pressures and other factors associated with the
.