§ 255-131.   Lot, yard and bulk requirements.
   A.    . The maximum permitted in the MRD shall be 2.75 per acre (excluding the rights-of-way of existing public ).
   B.   Mixing requirements. For any MRD, a minimum of 35% shall be constructed as single-family detached and single-family patio . At least 40% of the 35% shall be single-family detached, with the remaining units patio . At least two additional housing types must be included in the MRD, no one of which shall be more than 40% of the total number of units.
   C.   Impervious coverage. Impervious coverage for the entire MRD shall not exceed 35%.
   D.    .
      (1)    . A minimum of not less than 15,000 square feet (s.f.) shall be provided.
      (2)    width. A width of not less than 80 feet shall be required at the   .
      (3)   Front . A front of not less than 35 feet in depth shall be required from the .
      (4)   Side . Two side , together having an aggregate width not less than 25 feet, but neither having a width less than 10 feet, shall be required.
      (5)   Rear . A rear of not less in depth than 30 feet shall be required.
   E.   Single-family patio .
      (1)    . A minimum of not less than 7,000 square feet shall be provided, with an average of not less than 9,000 square feet being provided.
      (2)    width. A width of not less than 60 feet shall be required at the   .
      (3)   Front requirements. A front of not less than 30 feet in depth shall be required from the .
      (4)   Side . One side of not less than 15 feet shall be required.
      (5)   Rear . A rear of not less in depth than 25 feet shall be required.
      (6)   When the wall of a is constructed on the side line of a , the deed to the adjacent shall reserve an easement to permit the maintenance and reconstruction of the said .
   F.    and .
      (1)    . A minimum of not less than 2,500 square feet shall be provided, with an average of not less than 3,000 square feet being provided.
      (2)    width. A width of not less than 20 feet shall be required at the   .
      (3)   Front . A front of not less than 20 feet in depth shall be required from the   .
      (4)   Side (end of row). One side at each end of the row, not less than 15 feet in width, shall be required.
      (5)   Rear . A rear of not less in depth than 25 feet shall be required.
   G.    .
      (1)    . A minimum of not less than 6,000 square feet shall be provided per .
      (2)    width. A width of not less than 40 feet shall be required at the   .
      (3)   Front . A front of not less than 20 feet in depth shall be required from the .
      (4)   Side . One side , not less than 15 feet in width, shall be required.
      (5)   Rear . A rear of not less in depth than 25 feet shall be required.
   H.    .
      (1)    . The net of any multiplex area shall not exceed eight per acre. (The net shall be calculated on an area which included the multiplex , parking and adjacent open space intended for the residents along with all required multiplex spaces established by setback requirements. The area shall specifically exclude all devoted to other than ).
      (2)    length. The total length of any shall not exceed 140 feet in any one direction.
      (3)   Distance between . The distance between multiplex shall not be less than 20 feet end-to-end or 50 feet side-by-side and shall comply with BOCA Code fire resistance ratings. 35
      (4)    setbacks.
         (a)   Setback from property lines. A setback from the property lines of not less than 300 feet shall be required, except where one of the major frontages is primarily along a or .
         (b)   Setback; interdevelopment. A setback from the of adjacent residential of not less than 50 feet in depth shall be required.
         (c)   Setback from . A setback from the of public of not less than 40 feet in depth and from of not less than 20 feet in depth shall be required.
         (d)   Rear setback. A setback of not less than 25 feet from the rear shall be required. [Added 2-13-1996 by Ord. No. 904]
   I.   All shall have access to a public .
   J.   The proposed shall be served by both centralized sewer and water facilities deemed acceptable by the Board of Commissioners.
35. Editor's Note: See Ch. 117, Fire Prevention.