§ 10.192.060   Loading facilities.
   This section contains standards to regulate the number, design and location of off-street loading areas, to ensure the following:
   (A)   Applicability. Off-street loading areas shall be consistent with the following requirements:
   (B)   Number of loading spaces required. 
      (1)   Commercial, industrial, office, institutional, hospital, hotel, schools.
 
Loading Spaces Required
Less than 5,000 square feet of gross floor area
0
5,000 to 25,000 square feet of gross floor area
1
Over 25,000 square feet of gross floor area
1 + as required by the Planning and Building Director
 
      (2)   Design standards.
         (a)   Location. To the extent possible, loading facilities should be located at the rear of the building which they serve.
         (b)   Access. All loading spaces shall be accessible from a public street or alley, but shall be designed to preclude the need to use any public streets for maneuvering or backing trailers into the loading space.
         (c)   Dimensions.
            1.   Minimum length: 25 feet.
            2.   Minimum width: 12 feet.
            3.   Minimum overhead clearance: 14 feet.
         (d)   Surfacing. The loading area, aisles and access drives shall be paved to provide a durable, dustless surface and shall be graded to properly dispose of surface water.
         (e)   Lighting. Loading areas shall be lighted to provide adequate illumination for security and safety. Lighting fixtures shall be in scale with the size and use of the structure. Any illumination shall be installed so as not to cause a nuisance to adjoining properties.
         (f)   Noise reduction. Where a loading facility will be in close proximity to residential or other noise-sensitive uses, noise reduction measures (such as a seven-foot tall masonry wall combined with landscaping) may be required.
(1995 Code, § 10.192.060) (Ord. 07-27, passed 12-18-2007; Ord. 00-1854, passed - -2000)