(A) The following sections of the 2012 International Residential Code are revised and amended as follows:
(1) Section 101.1 is hereby amended by substituting “City of Troy, Illinois” for the words “[NAME OF JURISDICTION]” and by adding the sentence, “The term “jurisdiction” wherever appearing in this code shall mean the City of Troy, Illinois.
(2) Section R309.5 Fire Sprinklers is deleted in its entirety and inserted in its place is the following: “R309.5 Separation required. The garage shall be separated from the residence and its attic area by not less than 1/2-inch (12.7 mm) gypsum board applied to the garage side. Garages beneath habitable rooms shall be separated from all habitable rooms above by not less than 5/8-inch (15.9 mm) Type X gypsum board or equivalent. Where the separation is a floor-ceiling assembly, the structure supporting the separation shall also be protected by not less than 1/2-inch (12.7 mm) gypsum board or equivalent.”
(3) Section E3902.12 Arc-Fault Circuit-Interrupter Protection is amended to read as follows: “All branch circuits that supply 125 volt, single phase, 15 or 20 ampere outlets installed in dwelling unit bedrooms shall be protected by an arc-fault circuit interrupter to provide protection of the entire branch circuit.”
(B) The following sections of the 2012 International Residential Code are hereby deleted:
(1) Section 113 Means of Appeal is deleted in its entirety.
(2) Section R313 Automatic Fire Sprinkler Systems is deleted in its entirety.
(3) Sections R402.1 through R402.1.2 Wood Foundations are deleted in their entirety.
(4) Figures R403.i(2) and 11403.1(3) Permanent Wood Foundations are deleted in their entirety.
(5) Section R405.2 Wood Foundation is deleted in its entirely.
(6) Section R501.3 Fire Protection of Floors is deleted in its entirety.
(7) Chapter 25 Plumbing Administration, Chapter 26 General Plumbing Requirements, Chapter 27 Plumbing Fixtures, Chapter 28 Water Heaters, Chapter 29 Water Supply and Distribution, Chapter 30 Sanitary Drainage, Chapter 31 Plumbing Vents, and Chapter 32 Plumbing Traps are deleted in their entirety.
(8) Appendix P Sizing of Water Piping System is deleted in its entirety.
(C) The 2012 International Residential Code shall be administered by the Building Inspector.
(D) The penalties for violations of this code shall be those which are described in § 151.999.
(E) The fees for applications, permits and inspections shall be prescribed by the City Council.
(1986 Code, § 7-87) (Ord. 2006-05, passed 3-6-2006; Ord. 2013-09, passed 8-5-2013) Penalty, see § 151.999