§ 53.59 EQUIVALENT DOMESTIC UNIT CHART.
Type of Establishment
Estimated Flow (Gallons per Day)
Type of Establishment
Estimated Flow (Gallons per Day)
Agricultural labor camp
50 per occupant
Airport
3 per passenger plus 20 per employee
Apartment
200 per 1-bedroom
300 per 2-bedroom
350 per 3-bedroom
Assembly hall
3 per seat
Bar (without food service)
10 per seat
Beauty salon
35 per customer
Bowling alley
   with bar and/or food
125 per lane
   without food service
75 per lane
Bus station
3 per passenger
Swimming pool bathhouse
10 per swimmer
Theater
   Drive-in
5 per car space
   Inside building
5 per seat
 
Type of Establishment
Estimated Flow (Gallons per Day)
Type of Establishment
Estimated Flow (Gallons per Day)
Campground
   Organizational
      with flush toilets
40 per camper
      without flush toilets
20 per camper
   Recreational
      with individual sewer connection (independent)
100 per campsite
      without individual sewer connection (dependent)
50 per campsite
Church
   with kitchen
5 per sanctuary seat
   without kitchen
3 per sanctuary seat
Condominiums
200 per 1-bedroom
300 per 2-bedroom
350 per 3-bedroom
Correctional facilities
120 per inmate
Day care center
20 per person
Dentist
750 per chair plus 75 per employee
Factory
   with showers
35 per employee
   without showers
20 per employee
Food service operations
   Cocktail lounge
35 per seat
   Curb service (drive-in)
50 per car space
   Restaurant (not 24-hour)
35 per seat
 
Type of Establishment
Estimated Flow (Gallons per Day)
Type of Establishment
Estimated Flow (Gallons per Day)
   Restaurant, 24-hour
50 per seat
   Restaurant, 24-hour, along interstate
70 per seat
   Tavern
35 per seat
Hospital, medical facilities
200 per bed
Hotel
100 per room
Kennels
20 per animal enclosure
Mental health facility
100 per patient
Mobile home park
200 per lot
Motel
100 per room
Nursing home
100 per bed
Office building
20 per employee
Outpatient surgical center
50 per patient
Picnic area
5 per visitor
School
   Elementary
15 per pupil
   Secondary
25 per pupil
Service station (gas station)
400 per restroom
Shopping center
0.1 per square foot of floor space, plus 20 per employee
 
(Ord. 2010-0003, passed 1-21-2010)