(A) The contractor shall be required to perform a closed circuit television inspection of the sanitary sewer between manholes prior to final acceptance if the sewer fails to pass the mandrel test as specified in this section. The contractor shall thoroughly clean the sewer before the camera is installed and televising is commenced.
(B) A camera equipped with remote control devices to adjust the light intensity and a minimum of 1,000 lineal feet of sewer cable shall be provided. The camera shall transmit a continuous image to the television monitor as it is being pulled through the pipe. The image shall be clear enough to enable the town representative and others viewing the monitor to easily evaluate the interior condition of the pipe. The camera should have a digital display for lineal footage and project number. The camera shall be equipped to pan not less than 180 degrees. An audio voice-over shall be made during the inspection identifying any problems encountered.
(C) The contractor shall provide a digital copy of the televising for the entire sewer line as well as a map indicating the pipe segment identification numbers of all pipe that has been televised. If any pipe or joint is found to be leaking, the contractor shall be required to repair that portion of the pipe to the satisfaction and approval of the town.
(Ord. 2019-8-26(A), passed 8-26-2019)